Literature DB >> 27859535

Marker-based technique for visualizing radiolucent implant components in radiographic imaging.

Kimberley Lam-Tin-Cheung1, Xunhua Yuan2, Hristo N Nikolov2, Brent A Lanting3, Douglas D Naudie3, Matthew G Teeter1,2,3,4.   

Abstract

Radiography is the predominant imaging modality used for the in-vivo analysis of orthopaedic implants. A major disadvantage of radiography is that the articulating joint components that are composed of radiolucent polyethylene cannot be directly visualized. Current strategies attempt to circumvent this limitation by estimating component positions and simplifying the joint system, however, these approaches lead to a number of associated errors. Thus, this study provides a method to enable the visualization of the polyethylene component of total knee replacements in radiographic images. This was achieved through the repeatable insertion of markers and accompanying registration process, which were evaluated in this study for reproducibility and accuracy. An insertion guide was developed to insert tantalum beads into polyethylene tibial surface liners. The bead-inserted liners were micro-CT scanned to obtain 3D surface geometries. An in-vivo mimicking phantom RSA experiment was then used to test the 3D to 2D registration process. The guide positioned the beads consistently to ±0.21 mm. The 3D to 2D registration demonstrated a repeatability of -0.014 ± 0.008 mm. Registration of different bead-inserted tibial liners to the phantom revealed an average error of 0.026 ± 0.047 mm for this visualization method. This visualization approach provides greatly improved registration and inter-component measurements than current alternative strategies. This process is suitable for a number of other joints and would greatly benefit procedures that analyze component interactions and implant performance over time.
© 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2017-2022, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  polyethylene visualization; radiographic imaging; radiostereometric analysis; three-dimensional registration; total knee replacement

Mesh:

Substances:

Year:  2016        PMID: 27859535     DOI: 10.1002/jor.23475

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  2 in total

1.  Radiostereometric Analysis Permits In Vivo Measurement of Very Small Levels of Wear in TKA.

Authors:  Matthew G Teeter; Jacob Wihlidal; Richard W McCalden; Xunhua Yuan; Steven J MacDonald; Brent A Lanting; Douglas D Naudie
Journal:  Clin Orthop Relat Res       Date:  2019-01       Impact factor: 4.176

2.  Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study.

Authors:  Peter Bo Jørgensen; Bart L Kaptein; Kjeld Søballe; Stig S Jakobsen; Maiken Stilling
Journal:  Eur Radiol Exp       Date:  2021-12-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.