Literature DB >> 27858683

The correlation between radiographic and surface topography assessments in three plane pelvic parameters.

Neveen A Abdel Raoof1, Kadrya H Battecha1, Salah Eldin B Elsayed1, Elsadat Saad Soliman2.   

Abstract

BACKGROUND: Noninvasive rasterstereography has been reported as a helpful tool for assessing pelvic parameters. However, the validation and reproducibility of this tool are still questionable.
OBJECTIVE: To investigate the correlation between video rasterstereography device (VRD) and X-ray photography in terms of validity and reproducibility (inter- and intra-examiner reliability) in pelvic parameters.
METHODS: Thirty male and female healthy subjects with a mean age (26.9 ± 4.9 years) participated in this study. Subjects were examined by VRD for three pelvic parameters (pelvic torsion, pelvic tilt, and pelvic inclination). Measurements were conducted by three different examiners. Subjects were examined by X-ray radiography for the same pelvic parameters as well. Pearson correlation coefficient (r) was used to examine the validity and Intra-class correlation coefficient (ICC) was used to check intra- and inter-examiner reliability.
RESULTS: For pelvic torsion, tilt, and inclination the validity levels of VRD were 0.867, 0.996, and 0.930 (P < 0.05), respectively; while the intra- and inter-examiner reliability coefficients were 0.999, 0.999, and 0.998 and 0.990, 0.997, and 0.989, respectively.
CONCLUSION: The results of this study revealed that the VRD has both high validity and reliability in assessing the selected three pelvic parameters that reflect the three fundamental planes of movement in healthy subjects. Further studies using VRD are recommended to assess low back pain-associated pelvic parameters.

Entities:  

Keywords:  Surface topography; pelvic parameters; reproducibility; validity

Year:  2016        PMID: 27858683     DOI: 10.3233/BMR-150444

Source DB:  PubMed          Journal:  J Back Musculoskelet Rehabil        ISSN: 1053-8127            Impact factor:   1.398


  2 in total

1.  Reliability of the DIERS Formetric 4D Spine Shape Parameters in Adults without Postural Deformities.

Authors:  Brian F Degenhardt; Zane Starks; Shalini Bhatia
Journal:  Biomed Res Int       Date:  2020-02-13       Impact factor: 3.411

2.  Biomechanical evaluation and comparison of clinically relevant versus non-relevant leg length inequalities.

Authors:  Roman Michalik; Viola Rissel; Filippo Migliorini; Hannah Lena Siebers; Marcel Betsch
Journal:  BMC Musculoskelet Disord       Date:  2022-02-23       Impact factor: 2.362

  2 in total