Literature DB >> 27858114

Safety of bailout stenting after paclitaxel-coated balloon angioplasty.

K H Mok1, U Wickramarachchi2, T Watson3,4, H H Ho1, S Eccleshall2, P J L Ong1.   

Abstract

BACKGROUND: Bailout stenting after suboptimal paclitaxel-coated balloon (PCB) angioplasty is required in up to 28% of cases. We sought to compare the safety of bailout stenting with drug-eluting stents (DES) compared with the more established combination of PCB with bare metal stents (BMS).
METHODS: We retrospectively evaluated all patients who had stents implanted owing to suboptimal PCB angioplasty results between January 2010 and April 2015. Endpoints analyzed were major adverse cardiac events (MACE) - defined as cardiovascular death, nonfatal myocardial infarction (MI), and target lesion revascularization (TLR) - as well as major and minor bleeding.
RESULTS: Baseline clinical characteristics were comparable with a high proportion of diabetics in both groups (50.0% vs. 45.8%, p = 0.74). BMS and DES sizes were similar (mean diameter 2.72 ± 0.50 mm vs. 2.89 ± 0.56 mm, p = 0.20, length 25.22 ± 13.47 mm vs. 28.08 ± 9.08 mm, p = 0.47). Outcomes were comparable at the end of 1 year (MACE 12.2% vs. 9.5%, p = 1.00, TLR 6.1% vs. 4.8%, p = 1.00, MI 0% vs. 4.8%, p = 0.30). There was no case of stent thrombosis or major bleeding, and the rates of minor bleeding were similar (4.2% vs. 4.8%, p = 1.00).
CONCLUSION: Our initial experience using DES instead of BMS as a bailout after suboptimal PCB results shows that the procedure is safe and effective at 1 year.

Entities:  

Keywords:  Balloon angioplasty; Coronary stenosis; Drug-eluting stents; Paclitaxel

Mesh:

Substances:

Year:  2016        PMID: 27858114     DOI: 10.1007/s00059-016-4502-9

Source DB:  PubMed          Journal:  Herz        ISSN: 0340-9937            Impact factor:   1.443


  27 in total

Review 1.  2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention: executive summary: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Society for Cardiovascular Angiography and Interventions.

Authors:  Glenn N Levine; Eric R Bates; James C Blankenship; Steven R Bailey; John A Bittl; Bojan Cercek; Charles E Chambers; Stephen G Ellis; Robert A Guyton; Steven M Hollenberg; Umesh N Khot; Richard A Lange; Laura Mauri; Roxana Mehran; Issam D Moussa; Debabrata Mukherjee; Brahmajee K Nallamothu; Henry H Ting
Journal:  Catheter Cardiovasc Interv       Date:  2012-02-15       Impact factor: 2.692

2.  Treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter.

Authors:  Bruno Scheller; Christoph Hehrlein; Wolfgang Bocksch; Wolfgang Rutsch; Dariush Haghi; Ulrich Dietz; Michael Böhm; Ulrich Speck
Journal:  N Engl J Med       Date:  2006-11-13       Impact factor: 91.245

Review 3.  Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern.

Authors:  Edoardo Camenzind; P Gabriel Steg; William Wijns
Journal:  Circulation       Date:  2007-03-07       Impact factor: 29.690

4.  Clinical efficacy of polymer-based paclitaxel-eluting stents in the treatment of complex, long coronary artery lesions from a multicenter, randomized trial: support for the use of drug-eluting stents in contemporary clinical practice.

Authors:  Keith D Dawkins; Eberhard Grube; Giulio Guagliumi; Adrian P Banning; Krzysztof Zmudka; Antonio Colombo; Leif Thuesen; Karl Hauptman; Jean Marco; William Wijns; Jeffrey J Popma; Joerg Koglin; Mary E Russell
Journal:  Circulation       Date:  2005-11-14       Impact factor: 29.690

5.  Bleeding complications with dual antiplatelet therapy among patients with stable vascular disease or risk factors for vascular disease: results from the Clopidogrel for High Atherothrombotic Risk and Ischemic Stabilization, Management, and Avoidance (CHARISMA) trial.

Authors:  Peter B Berger; Deepak L Bhatt; Valentin Fuster; P Gabriel Steg; Keith A A Fox; Mingyuan Shao; Danielle M Brennan; Werner Hacke; Gilles Montalescot; Steven R Steinhubl; Eric J Topol
Journal:  Circulation       Date:  2010-06-01       Impact factor: 29.690

6.  Angiographic, optical coherence tomography and histology findings from combination of a drug-coated balloon with an everolimus-eluting stent in a porcine model.

Authors:  Paul J L Ong; Takashi Kubo; Timothy J Watson; Agnes S P Seah; Philip E H Wong; Takashi Akasaka
Journal:  Int J Cardiol       Date:  2016-08-18       Impact factor: 4.164

Review 7.  Paclitaxel drug-coated balloons: a review of current status and emerging applications in native coronary artery de novo lesions.

Authors:  Joshua P Loh; Ron Waksman
Journal:  JACC Cardiovasc Interv       Date:  2012-10       Impact factor: 11.195

8.  Clinical outcomes and stent thrombosis following off-label use of drug-eluting stents.

Authors:  Htut K Win; Angel E Caldera; Kelly Maresh; John Lopez; Charanjit S Rihal; Manish A Parikh; Juan F Granada; Sachin Marulkar; Deborah Nassif; David J Cohen; Neal S Kleiman
Journal:  JAMA       Date:  2007-05-09       Impact factor: 56.272

9.  The role of drug-eluting balloons alone or in combination with drug-eluting stents in the treatment of de novo diffuse coronary disease.

Authors:  Charis Costopoulos; Azeem Latib; Toru Naganuma; Alessandro Sticchi; Filippo Figini; Sandeep Basavarajaiah; Mauro Carlino; Alaide Chieffo; Matteo Montorfano; Charbel Naim; Masanori Kawaguchi; Francesco Giannini; Antonio Colombo
Journal:  JACC Cardiovasc Interv       Date:  2013-11       Impact factor: 11.195

10.  Short- and long-term outcomes with drug-eluting and bare-metal coronary stents: a mixed-treatment comparison analysis of 117 762 patient-years of follow-up from randomized trials.

Authors:  Sripal Bangalore; Sunil Kumar; Mario Fusaro; Nicholas Amoroso; Michael J Attubato; Frederick Feit; Deepak L Bhatt; James Slater
Journal:  Circulation       Date:  2012-05-14       Impact factor: 29.690

View more
  2 in total

1.  DCB meets DES.

Authors:  F Krackhardt; M Noutsias; C Tschöpe; B Kherad
Journal:  Herz       Date:  2017-01-23       Impact factor: 1.443

2.  Drug-coated balloon treatment in coronary artery disease: Recommendations from an Asia-Pacific Consensus Group.

Authors:  Ae-Young Her; Eun-Seok Shin; Liew Houng Bang; Amin Ariff Nuruddin; Qiang Tang; I-Chang Hsieh; Jung-Cheng Hsu; Ong Tiong Kiam; ChunGuang Qiu; Jie Qian; Wan Azman Wan Ahmad; Rosli Mohd Ali
Journal:  Cardiol J       Date:  2019-09-30       Impact factor: 2.737

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.