Literature DB >> 27857506

Short- to mid-term results of ulna head replacement as both a primary and revision implant.

Tobias K A Baring1, Ravi Popat2, Ali Abdelwahab1, Barry Ferris3.   

Abstract

We present the results of short- to medium-term follow-up of 10 patients following ulna head replacement. The mean age of patients was 63.2 years (range 48-81 years), with the mean duration of follow-up being 48 months (12-88 months). The indications for the procedure were primary osteoarthritis (n = 3), post-traumatic osteoarthritis (n = 4), failed Darrach's procedure (n = 2) and rheumatoid arthritis (n = 1). Two patients required revision (20%), one for gross aseptic loosening of the stem and another for an initially oversized head. At final follow-up, the satisfactory rate was 90%. The mean VAS score was 2.4 (range 0-8). The average DASH score was 37 (range 0-72.5). Our study suggests that ulna head replacement can give satisfactory forearm function; however, concerns exist regarding bone resorption and tapering around the prosthesis, which may affect the long-term performance of the prosthesis. LEVEL OF EVIDENCE: IV.

Entities:  

Keywords:  Arthritis; Distal radio-ulna joint; Distal ulna replacement; Wrist arthroplasty

Year:  2016        PMID: 27857506      PMCID: PMC5106519          DOI: 10.1016/j.jcot.2016.04.005

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  22 in total

1.  Functional and radiographic outcomes following distal ulna implant arthroplasty.

Authors:  Sanjeev Kakar; R Presley Swann; Kevin I Perry; Christina M Wood-Wentz; Alexander Y Shin; Steven L Moran
Journal:  J Hand Surg Am       Date:  2012-07       Impact factor: 2.230

2.  Indications and early to mid-term results of ulnar head replacement.

Authors:  D Warwick; G Shyamalan; E Balabanidou
Journal:  Ann R Coll Surg Engl       Date:  2013-09       Impact factor: 1.891

3.  The load-bearing characteristics of the forearm: pattern of axial and bending force transmitted through ulna and radius.

Authors:  H Shaaban; G Giakas; M Bolton; R Williams; P Wicks; L R Scheker; V C Lees
Journal:  J Hand Surg Br       Date:  2006-02-07

4.  A study of functional outcomes following implantation of a total distal radioulnar joint prosthesis.

Authors:  L A Laurentin-Pérez; A N Goodwin; B A Babb; L R Scheker
Journal:  J Hand Surg Eur Vol       Date:  2008-02

Review 5.  Instability of the distal radioulnar articulation.

Authors:  W H Bowers
Journal:  Hand Clin       Date:  1991-05       Impact factor: 1.907

Review 6.  Distal radioulnar joint dysfunction.

Authors:  P C Dell
Journal:  Hand Clin       Date:  1987-11       Impact factor: 1.907

7.  Treatment of failed Sauvé-Kapandji procedures with a spherical ulnar head prosthesis.

Authors:  Diego L Fernandez; Elizabeth S Joneschild; Diego M Abella
Journal:  Clin Orthop Relat Res       Date:  2006-04       Impact factor: 4.176

8.  Ulnar Head Replacement: 21 Cases; Mean Follow-Up, 7.5 Years.

Authors:  Peter Axelsson; Christer Sollerman; Johan Kärrholm
Journal:  J Hand Surg Am       Date:  2015-07-26       Impact factor: 2.230

9.  The biomechanical stability of salvage procedures for distal radioulnar joint arthritis.

Authors:  Keith C Douglas; Brent G Parks; Michael A Tsai; Clifton G Meals; Kenneth R Means
Journal:  J Hand Surg Am       Date:  2014-05-13       Impact factor: 2.230

10.  Ulnar impingement syndrome.

Authors:  M J Bell; R J Hill; R Y McMurtry
Journal:  J Bone Joint Surg Br       Date:  1985-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.