| Literature DB >> 27855775 |
Gaurav M Sharma1, Gauresh Palekar1, Dilip D Tanna1.
Abstract
PURPOSE: The age-old practice of closed suction drain following orthopedic procedures has been challenged since past few decades. Our aim was to assess the effectiveness of closed suction drain after total knee arthroplasty.Entities:
Year: 2016 PMID: 27855775 PMCID: PMC5115035 DOI: 10.1051/sicotj/2016034
Source DB: PubMed Journal: SICOT J ISSN: 2426-8887
Different variables like hemoglobin (Hb), dressing change, early infection, ecchymosis, decreased range of movements, and duration of hospital stay.
| Variable | Study group ( | Control group ( | Test of significance used |
|
|---|---|---|---|---|
| Pre-operative hemoglobin | 12.1678 ± 1.3220 | 12.1803 ± 1.2717 | Two sample independent | 0.9563 |
| Post-operative hemoglobin | 9.8373 ± 1.5703 | 9.7918 ± 1.4163 | Two sample independent | 0.8681 |
| Dressing change within 24 h | 7 (11.8) | 3 (4.9) | Fisher’s exact | 0.2043 |
| Early infection | 1 (1.69) | 1 (1.63) | Fisher’s exact | 1.0000 |
| Ecchymosis | 3 (5.08) | 2 (3.2) | Fisher’s exact | 0.6769 |
| Decreased range of movements | 2 (3.3) | 6 (9.8) | Fisher’s exact | 0.2727 |
| Duration of hospital stay | 5.12 ± 1.65 | 6.21 ± 1.74 | Two sample independent | 0.0006 |
Statistically significant.
WOMAC index.
| Variables | Drain ( | No drain ( |
|
|
|---|---|---|---|---|
| Pre-Op | 12.3623 ± 4.0016 | 13.0017 ± 4.3021 | 0.8418 | 0.4016 |
| Two weeks | 30.1721 ± 5.1560 | 30.1814 ± 5.1047 | 0.0096 | 0.9924 |
| Six months | 52.1593 ± 7.3826 | 52.8770 ± 9.9231 | 0.4485 | 0.6547 |
| One year | 83.6443 ± 8.7956 | 83.8966 ± 8.4728 | 0.1599 | 0.8733 |
Oxford knee scoring (OKS).
| Variables | Drain control ( | No drain study ( |
|
|
|---|---|---|---|---|
| Pre-Op | 10.796 ± 2.8814 | 10.389 ± 3.0739 | 0.7478 | 0.4561 |
| Two weeks | 24.1803 ± 3.7617 | 24.1356 ± 3.6410 | 0.0666 | 0.947 |
| Six months | 34.48 ± 4.1066 | 33.9661 ± 3.8639 | 0.7064 | 0.4814 |
| One year | 43.2787 ± 3.4647 | 43.2712 ± 3.5807 | 0.0109 | 0.9913 |
Figure 1.Discharge from the drain site.