Prospective Identification of Stent Fracture by Enhanced Stent Visualization System During Percutaneous Coronary Intervention.

Simone Biscaglia1, Matteo Tebaldi, Carlo Tumscitz, Rita Pavasini, Jlenia Marchesini, Francesco Gallo, Giosafat Spitaleri, Fatima Zaraket, Matteo Serenelli, Paolo Cimaglia, Giulia Bugani, Gianluca Campo.   

Abstract

BACKGROUND: No study has evaluated the clinical consequences of stent fracture (SF) detected during the index percutaneous coronary intervention (PCI). Thus, we sought to investigate the relationship between SF detected during PCI and clinical outcome.Methods and 
Results: We consecutively enrolled 832 patients with SF-predisposing factors undergoing 2nd-generation drug-eluting stent implantation and enhanced stent visualization (ESV) system evaluation to detect SF at index PCI. The primary endpoint was a 9-month device-oriented endpoint (DOCE, including cardiac death, target vessel myocardial infarction, and target lesion revascularization). We observed 136 SF in 115 patients (14% of study population). SF I-II was present in 78 patients (68% of patients with SF), and SF III-IV occurred in 37 patients (32%). DOCE at 9 months occurred in 135 patients (16% of the overall population). There was a significant difference in DOCE occurrence between the 3 groups (P=0.006 at log-rank), driven by the SF III-IV group (P=0.001 vs. no SF group, and P=0.01 vs. SF I-II group). In 23 cases of SF III-IV (62%) a further stent was implanted. DOCE occurrence was significantly higher in patients with "untreated" type III-IV SF as compared with the "treated" ones (9% vs. 79%, P<0.01).
CONCLUSIONS: The ESV system is helpful in detecting SF during the index PCI. Type III-IV SFs are associated with a higher incidence of DOCE.

Entities:  

Mesh:

Year:  2016        PMID: 27853098     DOI: 10.1253/circj.CJ-16-0785

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  4 in total

1.  Re-crossing the distal cell in bifurcation verified by using an enhanced stent visualization system and optical coherence tomography: a report of two cases.

Authors:  Ruofei Jia; Zening Jin; Hong Li; Jing Han
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

Review 2.  BRS implantation in long lesions requiring device overlapping: myth or reality?

Authors:  Simone Biscaglia; Andrea Erriquez; Davide Bernucci; Giulia Bugani; Enrico Favaretto; Gianluca Campo
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

Review 3.  Drug-eluting stent thrombosis: current and future perspectives.

Authors:  Shoichi Kuramitsu; Shinjo Sonoda; Kenji Ando; Hiromasa Otake; Masahiro Natsuaki; Reo Anai; Yasuhiro Honda; Kazushige Kadota; Yoshio Kobayashi; Takeshi Kimura
Journal:  Cardiovasc Interv Ther       Date:  2021-01-13

4.  An Interesting Case and Literature Review of a Coronary Stent Fracture in a Current Generation Platinum Chromium Everolimus-Eluting Stent.

Authors:  Sammy San Myint Aung; Htun Latt; Kyaw Kyaw; Chanwit Roongsritong
Journal:  Case Rep Cardiol       Date:  2018-06-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.