Literature DB >> 27852498

Evaluation of Limited Screw Density Pedicle Screw Constructs in Posterior Fusions for Adolescent Idiopathic Scoliosis.

John W Kemppainen1, Melanie A Morscher2, M David Gothard3, Mark J Adamczyk2, Todd F Ritzman4.   

Abstract

STUDY
DESIGN: Retrospective case series.
OBJECTIVES: To compare radiographic and clinical outcomes in posterior spine fusions with pedicle screw instrumentation of varying screw densities in the treatment of adolescent idiopathic scoliosis (AIS). SUMMARY OF BACKGROUND DATA: Posterior spinal fusion with pedicle screw instrumentation is the mainstay of surgical treatment for AIS. The most commonly used construct consists of screws placed at every level on the concave side of the deformity and nearly every level on the convex side. However, some surgeons have begun using constructs with fewer pedicle screws. The literature comparing outcomes of these differing pedicle screw constructs is limited.
METHODS: Fifty-two consecutive cases of posterior spinal fusions for AIS performed by four surgeons were reviewed. High screw density constructs were used in 26 cases and limited screw density constructs in 26 cases. Construct characteristics and radiographic measurements were compared preoperatively and at last follow-up. Operative time and estimated costs were also evaluated. Student t tests were used to compare the groups with p < .05 considered significant.
RESULTS: There was no significant difference in magnitude of correction for the high versus limited screw density group initially (38.5° vs. 34.9°, p = .093) or at final follow-up (36.9° vs. 32.2°, p = .054). Sagittal alignment, coronal balance, and translation of the major apical vertebra were comparable and stable in both groups. The high versus limited screw density group utilized significantly more pedicle screws (16.8 vs. 11.6 screws, p < .0001), had longer operative times (309 vs. 267 minutes, p = .007), and had additional estimated direct costs of $5,800.
CONCLUSIONS: Excellent curve correction, stability, and balance can be achieved using fewer screws than commonly used in posterior pedicle screw fusions for AIS. Operative time is reduced, and risk and cost are decreased with the use of limited screw density constructs. LEVEL OF EVIDENCE: III.
Copyright © 2016 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Adolescent idiopathic scoliosis (AIS); Instrumentation constructs; Pedicle screws; Posterior spinal fusion; Screw-density

Mesh:

Year:  2015        PMID: 27852498     DOI: 10.1016/j.jspd.2015.07.010

Source DB:  PubMed          Journal:  Spine Deform        ISSN: 2212-134X


  7 in total

1.  The implant density does not change the correction rate of the main and the accompanying curves: A comparison between consecutive and intermittent pedicle screw constructs.

Authors:  Alpaslan Şenköylü; Mehmet Çetinkaya; İsmail Daldal; Ali Eren; Erdem Aktaş
Journal:  Acta Orthop Traumatol Turc       Date:  2020-05       Impact factor: 1.511

Review 2.  Perioperative outcome and complications following single-staged Posterior Spinal Fusion (PSF) using pedicle screw instrumentation in Adolescent Idiopathic Scoliosis (AIS): a review of 1057 cases from a single centre.

Authors:  Mun Keong Kwan; Kwong Weng Loh; Weng Hong Chung; Chee Kidd Chiu; Mohd Shahnaz Hasan; Chris Yin Wei Chan
Journal:  BMC Musculoskelet Disord       Date:  2021-05-04       Impact factor: 2.362

3.  Correction objectives have higher impact than screw pattern and density on the optimal 3D correction of thoracic AIS: a biomechanical study.

Authors:  Luigi La Barbera; A Noelle Larson; Carl-Eric Aubin
Journal:  Spine Deform       Date:  2021-01-26

4.  Comparison of low density and high density pedicle screw instrumentation in Lenke 1 adolescent idiopathic scoliosis.

Authors:  Mingkui Shen; Honghui Jiang; Ming Luo; Wengang Wang; Ning Li; Lulu Wang; Lei Xia
Journal:  BMC Musculoskelet Disord       Date:  2017-08-02       Impact factor: 2.362

5.  Reciprocal Changes in Sagittal Alignment in Adolescent Idiopathic Scoliosis Patients Following Strategic Pedicle Screw Fixation.

Authors:  Srikanth Reddy Dumpa; Ajoy Prasad Shetty; Siddharth N Aiyer; Rishi Mugesh Kanna; S Rajasekaran
Journal:  Asian Spine J       Date:  2018-04-16

6.  Impact of metal density on deformity correction in posterior fusions for adolescent idiopathic scoliosis: A retrospective cohort study.

Authors:  Irfan Qadir; Abdullah Shah; Syed Roman Alam; Haseeb Hussain; Rizwan Akram; Amer Aziz
Journal:  Ann Med Surg (Lond)       Date:  2020-03-10

7.  The correlations between the anchor density and the curve correction of adolescent idiopathic scoliosis surgery.

Authors:  Yu-Cheng Yeh; Chi-Chien Niu; Lih-Huei Chen; Wen-Jer Chen; Po-Liang Lai
Journal:  BMC Musculoskelet Disord       Date:  2019-10-27       Impact factor: 2.362

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.