Literature DB >> 27847109

Modified zeolitic imidazolate framework-8 as solid-phase microextraction Arrow coating for sampling of amines in wastewater and food samples followed by gas chromatography-mass spectrometry.

Hangzhen Lan1, Tuukka Rönkkö1, Jevgeni Parshintsev1, Kari Hartonen1, Ning Gan2, Motolani Sakeye3, Jawad Sarfraz3, Marja-Liisa Riekkola4.   

Abstract

In this study, a novel solid phase microextration (SPME) Arrow was prepared for the sampling of volatile low molecular weight alkylamines (trimethylamine (TMA) and triethylamine (TEA)) in wastewater, salmon and mushroom samples before gas chromatographic separation with mass spectrometer as detector. Acidified zeolitic imidazolate framework-8 (A-ZIF-8) was utilized as adsorbent and poly(vinyl chloride) (PVC) as the adhesive. The custom SPME Arrow was fabricated via a physical adhesion: (1) ZIF-8 particles were suspended in a mixture of tetrahydrofuran (THF) and PVC to form a homogeneous suspension, (2) a non-coated stainless steel SPME Arrow was dipped in the ZIF-8/PVC suspension for several times to obtain a uniform and thick coating, (3) the pore size of ZIF-8 was modified by headspace exposure to hydrochloric acid in order to increase the extraction efficiency for amines. The effect of ZIF-8 concentration in PVC solution, dipping cycles and aging temperature on extraction efficiency was investigated. In addition, sampling parameters such as NaCl concentration, sample volume, extraction time, potassium hydroxide concentration, desorption temperature and desorption time were optimized. The Arrow-to-Arrow reproducibilities (RSDs) for five ZIF-8 coated Arrows were 15.6% and 13.3% for TMA and TEA, respectively. The extraction with A-ZIF-8/PVC Arrow was highly reproducible for at least 130 cycles without noticeable decrease of performance (RSD<12.5%). Headspace SPME of 7.5mL sample solution with the fabricated ZIF-8 coated Arrow achieved linear ranges of 1-200ngmL-1 for both TMA and TEA. The limit of quantitation (LOQ) was 1ngmL-1 for both TMA and TEA. The method was successfully applied to the determination of TMA and TEA in wastewater, salmon and mushroom samples giving satisfactory selectivity towards the studied amines.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Acidified zeolitic imidazolate framework-8; Amines; Food; Gas chromatography–mass spectrometry; Solid phase microextraction Arrow; Wastewater

Mesh:

Substances:

Year:  2016        PMID: 27847109     DOI: 10.1016/j.chroma.2016.10.081

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  7 in total

1.  Ordered macro/micro-porous metal-organic framework of type ZIF-8 in a steel fiber as a sorbent for solid-phase microextraction of BTEX.

Authors:  Fernando Maya; Milad Ghani
Journal:  Mikrochim Acta       Date:  2019-06-11       Impact factor: 5.833

2.  Braid solid-phase microextraction of polycyclic aromatic hydrocarbons by using fibers coated with silver-based nanomaterials in combination with HPLC with fluorometric detection.

Authors:  Adrián Gutiérrez-Serpa; Daniel Schorn-García; Francisco Jiménez-Moreno; Ana I Jiménez-Abizanda; Verónica Pino
Journal:  Mikrochim Acta       Date:  2019-04-29       Impact factor: 5.833

3.  Selective extraction of aliphatic amines by functionalized mesoporous silica-coated solid phase microextraction Arrow.

Authors:  Hangzhen Lan; Wenzhong Zhang; Jan-Henrik Smått; Risto T Koivula; Kari Hartonen; Marja-Liisa Riekkola
Journal:  Mikrochim Acta       Date:  2019-06-11       Impact factor: 5.833

Review 4.  Novel Approaches Utilizing Metal-Organic Framework Composites for the Extraction of Organic Compounds and Metal Traces from Fish and Seafood.

Authors:  Sofia C Vardali; Natalia Manousi; Mariusz Barczak; Dimitrios A Giannakoudakis
Journal:  Molecules       Date:  2020-01-24       Impact factor: 4.411

5.  Optimization of SPME-Arrow-GC/MS Method for Determination of Free and Bound Volatile Organic Compounds from Grape Skins.

Authors:  Iva Šikuten; Petra Štambuk; Jasminka Karoglan Kontić; Edi Maletić; Ivana Tomaz; Darko Preiner
Journal:  Molecules       Date:  2021-12-06       Impact factor: 4.411

6.  A Simple Step toward Enhancing Hydrothermal Stability of ZIF-8.

Authors:  Shunsuke Tanaka; Yasuhito Tanaka
Journal:  ACS Omega       Date:  2019-11-12

7.  Ultra-Sensitive, Rapid and On-Site Sensing Harmful Ingredients Used in Aquaculture with Magnetic Fluid SERS.

Authors:  Meizhen Zhang; Jingru Liao; Xianming Kong; Qian Yu; Miao Zhang; Alan X Wang
Journal:  Biosensors (Basel)       Date:  2022-03-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.