Literature DB >> 2784647

Diaphragm pacing in infants and children. A life-table analysis of implanted components.

D E Weese-Mayer1, A S Morrow, R T Brouillette, M N Ilbawi, C E Hunt.   

Abstract

Since 1976, we have implanted bilateral phrenic nerve electrodes for diaphragm pacing in 33 infants and children. This population includes 23 patients with congenital central hypoventilation syndrome (CHS), two with late onset CHS and hypothalamic dysfunction, three with hypoventilation associated with Chiari II malformation and myelomeningocele, and five with quadriplegia. Our experience, totalling 192 system-years and 96 patient-years of pacing, has enabled us to document the nature and frequency of problems related to the implanted components of the Avery Laboratories (S-232-1) pacemaker system when used in a pediatric population. By life table analysis, the mean time to need for replacement of any implanted component was 56.3 months. A total of 26 failures requiring component replacement occurred and were classified into four types: (1) receiver failure (15 cases), (2) electrode wire or wire insulation breakage (six cases), (3) infection requiring diaphragm pacer system removal (three cases), and (4) mechanical nerve injury (two cases). We conclude that the present diaphragm pacing system is effective but not without risk of biomedical component failure. The present system might be substantially improved by (1) a modified receiver design with a hermetic seal to prevent fluid penetration, (2) stronger, better insulated electrode wires, and (3) modifications of surgical technique and electrode type to prevent phrenic nerve damage.

Entities:  

Mesh:

Year:  1989        PMID: 2784647     DOI: 10.1164/ajrccm/139.4.974

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  5 in total

1.  Neural morphological effects of long-term implantation of the self-sizing spiral cuff nerve electrode.

Authors:  E Romero; J F Denef; J Delbeke; A Robert; C Veraart
Journal:  Med Biol Eng Comput       Date:  2001-01       Impact factor: 2.602

2.  Intelligent volume-assured pressured support (iVAPS) for the treatment of congenital central hypoventilation syndrome.

Authors:  Abdullah Khayat; Debra Medin; Faiza Syed; Theo J Moraes; Saadoun Bin-Hasan; Indra Narang; Suhail Al-Saleh; Reshma Amin
Journal:  Sleep Breath       Date:  2017-02-11       Impact factor: 2.816

3.  Inspiratory muscle pacing in spinal cord injury: case report and clinical commentary.

Authors:  Anthony F DiMarco; Raymond P Onders; Anthony Ignagni; Krzysztof E Kowalski
Journal:  J Spinal Cord Med       Date:  2006       Impact factor: 1.985

4.  Plasma-assisted atomic layer deposition of Al(2)O(3) and parylene C bi-layer encapsulation for chronic implantable electronics.

Authors:  Xianzong Xie; Loren Rieth; Srinivas Merugu; Prashant Tathireddy; Florian Solzbacher
Journal:  Appl Phys Lett       Date:  2012-08-27       Impact factor: 3.791

Review 5.  Guidelines for diagnosis and management of congenital central hypoventilation syndrome.

Authors:  Ha Trang; Martin Samuels; Isabella Ceccherini; Matthias Frerick; Maria Angeles Garcia-Teresa; Jochen Peters; Johannes Schoeber; Marek Migdal; Agneta Markstrom; Giancarlo Ottonello; Raffaele Piumelli; Maria Helena Estevao; Irena Senecic-Cala; Barbara Gnidovec-Strazisar; Andreas Pfleger; Raquel Porto-Abal; Miriam Katz-Salamon
Journal:  Orphanet J Rare Dis       Date:  2020-09-21       Impact factor: 4.123

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.