Literature DB >> 27845874

Initial Single-Center Experience With the Fully Repositionable Transfemoral Lotus Aortic Valve System.

Kai-Uwe Jarr, Florian Leuschner, Benjamin Meder, Hugo A Katus, Raffi Bekeredjian, Emmanuel Chorianopoulos1.   

Abstract

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has become the standard therapy for patients with severe symptomatic aortic stenosis and unacceptable high risk for surgical aortic valve replacement. Several different devices for TAVR have been introduced so far, each of them with unique features. AIMS: To analyze our first real-world experience with the second- generation, mechanically expanded, fully repositionable transfemoral Lotus TAVR device (Boston Scientific).
RESULTS: Between August 2014 and January 2016, a total of 298 patients were scheduled for transfemoral TAVR at our institution. Among them, 145 patients received a CoreValve/CoreValve Evolut R device (Medtronic), 90 patients received a Sapien 3 device (Edwards Lifesciences), and 63 patients were scheduled for Lotus TAVR device implantation based on access vessel size and annulus diameter. Of the 63 subsequent patients scheduled, 62 were successfully implanted. Short-term Valve Academic Research Consortium (VARC)-2 results at 30 days showed a 6.4% all-cause mortality, a 3.2% major stroke rate, a 36.5% new permanent pacemaker rate and 1.6% major vascular complications. Of note was the near absence of significant residual aortic regurgitation in the presence of a favorable hemodynamic profile even in patients with difficult anatomy.
CONCLUSION: Our first real-time experience with the fully repositionable Lotus TAVR system mimics the results of early clinical studies like REPRISE II. Further next-generation modifications in combination with gaining experience with this new device will likely reduce the need for new permanent pacemaker implantation and vascular complications in the future.

Entities:  

Mesh:

Year:  2016        PMID: 27845874

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  2 in total

1.  Network meta-analysis of new-generation valves for transcatheter aortic valve implantation.

Authors:  Hisato Takagi; Yosuke Hari; Kouki Nakashima; Toshiki Kuno; Tomo Ando
Journal:  Heart Vessels       Date:  2019-05-29       Impact factor: 2.037

2.  Transcatheter aortic valve replacement with Lotus and Sapien 3 prosthetic valves: a systematic review and meta-analysis.

Authors:  Mirosław Gozdek; Jakub Ratajczak; Adam Arndt; Kamil Zieliński; Michał Pasierski; Matteo Matteucci; Dario Fina; Federica Jiritano; Paolo Meani; Giuseppe Maria Raffa; Pietro Giorgio Malvindi; Michele Pilato; Domenico Paparella; Artur Słomka; Uri Landes; Ran Kornowski; Jacek Kubica; Roberto Lorusso; Piotr Suwalski; Mariusz Kowalewski
Journal:  J Thorac Dis       Date:  2020-03       Impact factor: 3.005

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.