Literature DB >> 27845658

Shear Wave Imaging of Breast Tissue by Color Doppler Shear Wave Elastography.

Yoshiki Yamakoshi, Takahito Nakajima, Toshihiro Kasahara, Mayuko Yamazaki, Ren Koda, Naoki Sunaguchi.   

Abstract

Shear wave elastography is a distinctive method to access the viscoelastic characteristic of the soft tissue that is difficult to obtain by other imaging modalities. This paper proposes a novel shear wave elastography [color Doppler shear wave imaging (CD SWI)] for breast tissue. Continuous shear wave is produced by a small lightweight actuator, which is attached to the tissue surface. Shear wave wavefront that propagates in tissue is reconstructed as a binary pattern that consists of zero and the maximum flow velocities on color flow image (CFI). Neither any modifications of the ultrasound color flow imaging instrument nor a high frame rate ultrasound imaging instrument is required to obtain the shear wave wavefront map. However, two conditions of shear wave displacement amplitude and shear wave frequency are needed to obtain the map. However, these conditions are not severe restrictions in breast imaging. This is because the minimum displacement amplitude is [Formula: see text] for an ultrasonic wave frequency of 12 MHz and the shear wave frequency is available from several frequencies suited for breast imaging. Fourier analysis along time axis suppresses clutter noise in CFI. A directional filter extracts shear wave, which propagates in the forward direction. Several maps, such as shear wave phase, velocity, and propagation maps, are reconstructed by CD SWI. The accuracy of shear wave velocity measurement is evaluated for homogeneous agar gel phantom by comparing with the acoustic radiation force impulse method. The experimental results for breast tissue are shown for a shear wave frequency of 296.6 Hz.

Entities:  

Mesh:

Year:  2016        PMID: 27845658     DOI: 10.1109/TUFFC.2016.2626359

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  3 in total

1.  Shear wave velocity measurement of upper trapezius muscle by color Doppler shear wave imaging.

Authors:  Atsushi Yamamoto; Yoshiki Yamakoshi; Takashi Ohsawa; Hitoshi Shitara; Tsuyoshi Ichinose; Hiroyuki Shiozawa; Tsuyoshi Sasaki; Noritaka Hamano; Yasushi Yuminaka; Kenji Takagishi
Journal:  J Med Ultrason (2001)       Date:  2017-06-28       Impact factor: 1.314

2.  Application of the novel estimation method by shear wave elastography using vibrator to human skeletal muscle.

Authors:  Wakako Tsuchida; Yoshiki Yamakoshi; Shingo Matsuo; Mayu Asakawa; Keita Sugahara; Taizan Fukaya; Eiji Yamanaka; Yuji Asai; Naotaka Nitta; Toshihiko Ooie; Shigeyuki Suzuki
Journal:  Sci Rep       Date:  2020-12-17       Impact factor: 4.379

Review 3.  Breast Tumour Classification Using Ultrasound Elastography with Machine Learning: A Systematic Scoping Review.

Authors:  Ye-Jiao Mao; Hyo-Jung Lim; Ming Ni; Wai-Hin Yan; Duo Wai-Chi Wong; James Chung-Wai Cheung
Journal:  Cancers (Basel)       Date:  2022-01-12       Impact factor: 6.639

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.