Abstract
OBJECTIVES: Different light curing units are used for polymerization of composite resins. The aim of this study was to evaluate the degree of conversion (DC) and temperature rise in hybrid and low shrinkage composite resins cured by LED and Argon Laser curing lights.Entities:
Keywords: Argon laser; DC; LED; Low shrinkage composite; Temperature rise
Year: 2016 PMID: 27843507 PMCID: PMC5074004 DOI: 10.2174/1874210601610010538
Source DB: PubMed Journal: Open Dent J ISSN: 1874-2106
Characteristics of light curing units.
|
|
|
|
|
|---|---|---|---|
| Ultralume2 | Ultradent/USA | Diode | 40 s, 450 mw/s |
| Bluephase 16i | Ivoclar/Vivadent | High powered diode | 10 s, 1800 mw/s |
| Melles Griot | USA | Argon laser | 40 s, 500 mw/s |
Characteristics of composite resins.
|
|
|
|
|
|
|
|
|---|---|---|---|---|---|---|
| Filtek P90 | Low shrinkage | Silorane | Quartz, yttrium fluoride | 0.1-2 | 55% | 76% |
| Filtek Z250 | Hybrid | Bis-GMA, UDMA, | Zirconia/ Silica | 0.01-3.5 | 60% | 78% |
Temperature rise in different composite resins cured with different LCUs.
| LCUs | Composite | T1 (°С) | T2 (°С) | T3 (°С) | Tmax (s) |
|---|---|---|---|---|---|
| LED | Filtek Z250 | 11.43 ± 0.83 | 7.88± 0.78 | 3.5 ± 0.77 | 7.7 ± 0.82 |
| Filtek P90 | 21.45± 2.02 | 7.86±0.78 | 13.59±1.83 | 8±1.05 | |
| High Powered | Filtek Z250 | 11.81±1.49 | 7.72±0.72 | 4.09±1.51 | 4.4±0.52 |
| Filtek P90 | 26.25±1.75 | 7.62±1.02 | 18.63±2.24 | 4.3±0.48 | |
| Argon laser | Filtek Z250 | 7.86±0.95 | 3.41±0.36 | 4.45±0.93 | 8.4±0.96 |
| Filtek P90 | 13.12±1.7 | 3.17±0.35 | 9.95±1.87 | 9.7±1.15 |
DC in different composite resins cured with different LCUs.
| LCUs | Composite | DC(%) |
|---|---|---|
| LED | Z250 | 53.40± 5.60 |
| P90 | 50.61 ± 4.02 | |
| High Powered LED | Z250 | 56.79 ± 4.86 |
| P90 | 55.30±4.72 | |
| Argon Laser | Z250 | 55.23±5.17 |
| P90 | 53.82±5.05 |