Literature DB >> 27842783

Liquid Chromatography-Tandem Mass Spectrometry: An Emerging Technology in the Toxicology Laboratory.

Yan Victoria Zhang1, Bin Wei2, Yu Zhu3, Yanhua Zhang4, Martin H Bluth5.   

Abstract

In the last decade, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has seen enormous growth in routine toxicology laboratories. LC-MS/MS offers significant advantages over other traditional testing, such as immunoassay and gas chromatography-mass spectrometry methodologies. Major strengths of LC-MS/MS include improvement in specificity, flexibility, and sample throughput when compared with other technologies. Here, the basic principles of LC-MS/MS technology are reviewed, followed by advantages and disadvantages of this technology compared with other traditional techniques. In addition, toxicology applications of LC-MS/MS for simultaneous detection of large panels of analytes are presented.
Copyright © 2016 Elsevier Inc. All rights reserved.

Keywords:  APCI; APPI; ESI; Immunoassay; LC-MS/MS; MRM; Quadrupole mass spectrometer; Toxicology application

Mesh:

Year:  2016        PMID: 27842783     DOI: 10.1016/j.cll.2016.07.001

Source DB:  PubMed          Journal:  Clin Lab Med        ISSN: 0272-2712            Impact factor:   1.935


  5 in total

1.  The prevalence of liquid chromatography-tandem mass spectrometry confirmed paediatric poisoning at Red Cross War Memorial Children's Hospital, Cape Town, South Africa.

Authors:  Norbertta Washaya; Alicia Evans; Rudzani Muloiwa; Peter Smith; Heloise Buys
Journal:  BMC Pediatr       Date:  2021-01-18       Impact factor: 2.125

2.  Quantification of Teicoplanin Using the HPLC-UV Method for Clinical Applications in Critically Ill Patients in Korea.

Authors:  Jaeok Lee; Eun-Kyoung Chung; Sung-Wook Kang; Hwa-Jeong Lee; Sandy-Jeong Rhie
Journal:  Pharmaceutics       Date:  2021-04-17       Impact factor: 6.321

3.  A Difficult Challenge for the Clinical Laboratory: Accessing and Interpreting Manufacturer Cross-Reactivity Data for Immunoassays Used in Urine Drug Testing.

Authors:  Justine M Reschly-Krasowski; Matthew D Krasowski
Journal:  Acad Pathol       Date:  2018-11-21

4.  Hyphenated high-resolution mass spectrometry-the "all-in-one" device in analytical toxicology?

Authors:  Hans H Maurer
Journal:  Anal Bioanal Chem       Date:  2020-11-28       Impact factor: 4.142

5.  In vitro assays for characterization of distinct multiple catalytic activities of thyroid peroxidase using LC-MS/MS.

Authors:  Abhishek Tater; Aditi Gupta; Gopal Upadhyay; Abhay Deshpande; Rahul Date; Irfan Y Tamboli
Journal:  Curr Res Toxicol       Date:  2021-01-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.