Artifacts correction for T1rho imaging with constant amplitude spin-lock.

Weitian Chen1.   

Abstract

T1rho imaging with constant amplitude spin-lock is prone to artifacts in the presence of B1 RF and B0 field inhomogeneity. Despite significant technological progress, improvements on the robustness of constant amplitude spin-lock are necessary in order to use it for routine clinical practice. This work proposes methods to simultaneously correct for B1 RF and B0 field inhomogeneity in constant amplitude spin-lock. By setting the maximum B1 amplitude of the excitation adiabatic pulses equal to the expected constant amplitude spin-lock frequency, the spins become aligned along the effective field throughout the spin-lock process. This results in T1rho-weighted images free of artifacts, despite the spatial variation of the effective field caused by B1 RF and B0 field inhomogeneity. When the pulse is long, the relaxation effect during the adiabatic half passage may result in a non-negligible error in the mono-exponential relaxation model. A two-acquisition approach is presented to solve this issue. Simulation, phantom, and in-vivo scans demonstrate the proposed methods achieve superior image quality compared to existing methods, and that the two-acquisition method is effective in resolving the relaxation effect during the adiabatic half passage.
Copyright © 2016 Elsevier Inc. All rights reserved.

Keywords:  Artifacts; Spin-lock; T1rho

Year:  2016        PMID: 27842257     DOI: 10.1016/j.jmr.2016.11.002

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  4 in total

1.  Probing chemical exchange using quantitative spin-lock R asymmetry imaging with adiabatic RF pulses.

Authors:  Baiyan Jiang; Tao Jin; Thierry Blu; Weitian Chen
Journal:  Magn Reson Med       Date:  2019-06-24       Impact factor: 4.668

Review 2.  A comprehensive literatures update of clinical researches of superparamagnetic resonance iron oxide nanoparticles for magnetic resonance imaging.

Authors:  Yì Xiáng J Wáng; Jean-Marc Idée
Journal:  Quant Imaging Med Surg       Date:  2017-02

3.  Three-Dimensional GRE T mapping of the brain using tailored variable flip-angle scheduling.

Authors:  Casey P Johnson; Daniel R Thedens; Stanley J Kruger; Vincent A Magnotta
Journal:  Magn Reson Med       Date:  2020-02-12       Impact factor: 4.668

4.  Simultaneous T1 , T2 , and T relaxation mapping of the lower leg muscle with MR fingerprinting.

Authors:  Azadeh Sharafi; Katherine Medina; Marcelo W V Zibetti; Smita Rao; Martijn A Cloos; Ryan Brown; Ravinder R Regatte
Journal:  Magn Reson Med       Date:  2021-02-08       Impact factor: 3.737

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.