Literature DB >> 27841672

Calibration of Passive Samplers for the Monitoring of Pharmaceuticals in Water-Sampling Rate Variation.

Hanna Męczykowska1, Paulina Kobylis1, Piotr Stepnowski1, Magda Caban1.   

Abstract

Passive sampling is one of the most efficient methods of monitoring pharmaceuticals in environmental water. The reliability of the process relies on a correctly performed calibration experiment and a well-defined sampling rate (Rs) for target analytes. Therefore, in this review the state-of-the-art methods of passive sampler calibration for the most popular pharmaceuticals: antibiotics, hormones, β-blockers and non-steroidal anti-inflammatory drugs (NSAIDs), along with the sampling rate variation, were presented. The advantages and difficulties in laboratory and field calibration were pointed out, according to the needs of control of the exact conditions. Sampling rate calculating equations and all the factors affecting the Rs value - temperature, flow, pH, salinity of the donor phase and biofouling - were discussed. Moreover, various calibration parameters gathered from the literature published in the last 16 years, including the device types, were tabled and compared. What is evident is that the sampling rate values for pharmaceuticals are impacted by several factors, whose influence is still unclear and unpredictable, while there is a big gap in experimental data. It appears that the calibration procedure needs to be improved, for example, there is a significant deficiency of PRCs (Performance Reference Compounds) for pharmaceuticals. One of the suggestions is to introduce correction factors for Rs values estimated in laboratory conditions.

Entities:  

Keywords:  POCIS; Passive sampling; pharmaceutical residues; pharmaceuticals monitoring; sampling rates

Mesh:

Substances:

Year:  2016        PMID: 27841672     DOI: 10.1080/10408347.2016.1259063

Source DB:  PubMed          Journal:  Crit Rev Anal Chem        ISSN: 1040-8347            Impact factor:   6.535


  3 in total

Review 1.  The Influence of Ionic Liquids on the Effectiveness of Analytical Methods Used in the Monitoring of Human and Veterinary Pharmaceuticals in Biological and Environmental Samples-Trends and Perspectives.

Authors:  Natalia Treder; Tomasz Bączek; Katarzyna Wychodnik; Justyna Rogowska; Lidia Wolska; Alina Plenis
Journal:  Molecules       Date:  2020-01-10       Impact factor: 4.411

2.  Ionic liquids for the passive sampling of sulfonamides from water-applicability and selectivity study.

Authors:  Hanna Męczykowska; Paulina Kobylis; Piotr Stepnowski; Magda Caban
Journal:  Anal Bioanal Chem       Date:  2017-04-11       Impact factor: 4.142

3.  Development and application of an in-house library and workflow for gas chromatography-electron ionization-accurate-mass/high-resolution mass spectrometry screening of environmental samples.

Authors:  Verónica Castro; José Benito Quintana; Javier López-Vázquez; Nieves Carro; Julio Cobas; Denis Bilbao; Rafael Cela; Rosario Rodil
Journal:  Anal Bioanal Chem       Date:  2021-12-04       Impact factor: 4.478

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.