Literature DB >> 27837996

The influence of salt matrices on the reversed-phase liquid chromatography behavior and electrospray ionization tandem mass spectrometry detection of glyphosate, glufosinate, aminomethylphosphonic acid and 2-aminoethylphosphonic acid in water.

Wael Skeff1, Constantin Recknagel2, Detlef E Schulz-Bull2.   

Abstract

The analysis of highly polar and amphoteric compounds in seawater is a continuing challenge in analytical chemistry due to the possible formation of complexes with the metal cations present in salt-based matrices. Here we provide information for the development of analytical methods for glyphosate, glufosinate, AMPA, and 2-AEP in salt water, based on studies of the effects of salt matrices on reversed-phase liquid chromatography-heated electrospray ionization-tandem mass spectrometry (RP-LC-HESI-MS/MS) after derivatization of the target compounds with FMOC-Cl. The results showed that glyphosate was the only analyte with a strong tendency to form glyphosate-metal complexes (GMC), which clearly influenced the analysis. The retention times (RTs) of GMC and free glyphosate differed by approximately 7.00min, reflecting their distinct RP-LC behaviors. Divalent cations, but not monovalent (Na+, K+) or trivalent (Al3+, Fe3+) cations, contributed to this effect and their influence was concentration-dependent. In addition, Cu2+, Co2+, Zn2+, and Mn2+ prevented glyphosate detection whereas Ca2+, Mg2+, and Sr2+ altered the retention time. At certain tested concentrations of Ca2+ and Sr2+ glyphosate yielded two peaks, which violated the fundamental rule of LC, that under the same analytical conditions a single substance yields only one LC-peak with a specific RT. Salt-matrix-induced ion suppression was observed for all analytes, especially under high salt concentrations. For glyphosate and AMPA, the use of isotopically labeled internal standards well-corrected the salt-matrix effects, with better results achieved for glufosinate and 2-AEP with the AMPA internal standard than with the glyphosate internal standard. Thus, our study demonstrated that Ca2+, Mg2+, and Sr2+ can be used together with FMOC-Cl to form GMC-FMOC which is suitable for RP-LC-HESI-MS/MS analysis. Copyright Â
© 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  2-AEP; Complexes; Herbicides; MS/MS; Metabolite; RP-LC-HESI-; Salt matrix

Mesh:

Substances:

Year:  2016        PMID: 27837996     DOI: 10.1016/j.chroma.2016.11.007

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Analysis of glyphosate, aminomethylphosphonic acid, and glufosinate from human urine by HRAM LC-MS.

Authors:  Adrian A Franke; Xingnan Li; Jennifer F Lai
Journal:  Anal Bioanal Chem       Date:  2020-10-03       Impact factor: 4.142

2.  Capillary electrophoresis-mass spectrometry for the direct analysis of glyphosate: method development and application to beer beverages and environmental studies.

Authors:  Benedikt Wimmer; Martin Pattky; Leyla Gulu Zada; Martin Meixner; Stefan B Haderlein; Hans-Peter Zimmermann; Carolin Huhn
Journal:  Anal Bioanal Chem       Date:  2020-06-10       Impact factor: 4.142

3.  Analytical insight into degradation processes of aminopolyphosphonates as potential factors that induce cyanobacterial blooms.

Authors:  Damian Drzyzga; Jacek Lipok
Journal:  Environ Sci Pollut Res Int       Date:  2017-09-10       Impact factor: 4.223

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.