Literature DB >> 27837820

The cooperative effect of reduced graphene oxide and Triton X-114 on the electromembrane microextraction efficiency of Pramipexole as a model analyte in urine samples.

Armin Fashi1, Fatemeh Khanban2, Mohammad Reza Yaftian2, Abbasali Zamani3.   

Abstract

A new design of electromembrane microextraction coupled with high-performance liquid chromatography was developed for the determination of Pramipexole as a model analyte in urine samples. The presence of reduced graphene oxide in the membrane and Triton X-114 in the donor phase augments the extraction efficiency of Pramipexole by the proposed method. Dispersed reduced graphene oxide in the organic solvent was held in the pores of the fiber wall by capillary forces and sonication. It is possible that the immobilized reduced graphene oxide acts as a sorbent, affording an additional pathway for analyte transportation. Besides, the presence of Triton X-114 in the donor phase promotes effective migration of ionic analytes across the membrane. The parameters influencing the extraction procedure, such as type and concentration of surfactant, type of organic solvent, amount of reduced graphene oxide, sonication time, applied voltage, extraction time, ionic strength, pH of the donor and acceptor solutions, and stirring rate were optimized. The linear working ranges of the method for preconcentration- determination of Pramipexole in water and urine samples were found to be 0.13-1000 and 0.47-1000ngmL-1 with corresponding detection limits of 0.04 and 0.14ngmL-1, respectively. The proposed method allows achieving enrichment factors of 301 and 265 for preconcentration of the analyte in water and urine samples, respectively. The method was successfully applied for the determination of Pramipexole in the urine samples.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electromembrane extraction; Pramipexole; Reduced graphene oxide; Surfactant; Urine samples

Mesh:

Substances:

Year:  2016        PMID: 27837820     DOI: 10.1016/j.talanta.2016.09.067

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Solvent stir bar microextraction technique with three-hollow fiber configuration for trace determination of nitrite in river water samples.

Authors:  Hamid Badiee; Mohammad Ali Zanjanchi; Abbasali Zamani; Armin Fashi
Journal:  Environ Sci Pollut Res Int       Date:  2019-09-11       Impact factor: 4.223

Review 2.  Electromembrane extraction-Recent trends and where to go.

Authors:  Stig Pedersen-Bjergaard; Chuixiu Huang; Astrid Gjelstad
Journal:  J Pharm Anal       Date:  2017-04-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.