Energy flow analysis of amputee walking shows a proximally-directed transfer of energy in intact limbs, compared to a distally-directed transfer in prosthetic limbs at push-off.

R A Weinert-Aplin1, D Howard2, M Twiste3, H L Jarvis4, A N Bennett5, R J Baker6.   

Abstract

Reduced capacity and increased metabolic cost of walking occurs in amputees, despite advances in prosthetic componentry. Joint powers can quantify deficiencies in prosthetic gait, but do not reveal how energy is exchanged between limb segments. This study aimed to quantify these energy exchanges during amputee walking. Optical motion and forceplate data collected during walking at a self-selected speed for cohorts of 10 controls, 10 unilateral trans-tibial, 10 unilateral trans-femoral and 10 bilateral trans-femoral amputees were used to determine the energy exchanges between lower limb segments. At push-off, consistent thigh and shank segment powers were observed between amputee groups (1.12W/kg vs. 1.05W/kg for intact limbs and 0.97W/kg vs. 0.99W/kg for prosthetic limbs), and reduced prosthetic ankle power, particularly in trans-femoral amputees (3.12W/kg vs. 0.87W/kg). Proximally-directed energy exchange was observed in the intact limbs of amputees and controls, while prosthetic limbs displayed distally-directed energy exchanges at the knee and hip. This study used energy flow analysis to show a reversal in the direction in which energy is exchanged between prosthetic limb segments at push-off. This reversal was required to provide sufficient energy to propel the limb segments and is likely a direct result of the lack of push-off power at the prosthetic ankle, particularly in trans-femoral amputees, and leads to their increased metabolic cost of walking.
Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Energy exchange; Gait; Power; Prosthesis

Mesh:

Year:  2016        PMID: 27836575     DOI: 10.1016/j.medengphy.2016.10.005

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  3 in total

1.  The influence of a microprocessor-controlled hydraulic ankle on the kinetic symmetry of trans-tibial amputees during ramp walking: A case series.

Authors:  Michael McGrath; Piotr Laszczak; Saeed Zahedi; David Moser
Journal:  J Rehabil Assist Technol Eng       Date:  2018-10-08

2.  Prosthetic energy return during walking increases after 3 weeks of adaptation to a new device.

Authors:  Samuel F Ray; Shane R Wurdeman; Kota Z Takahashi
Journal:  J Neuroeng Rehabil       Date:  2018-01-27       Impact factor: 4.262

3.  Prosthetic push-off power in trans-tibial amputee level ground walking: A systematic review.

Authors:  Roy Müller; Lisa Tronicke; Rainer Abel; Knut Lechler
Journal:  PLoS One       Date:  2019-11-19       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.