Over-catheter tract suture to prevent bleeding and air embolism after tunnelled catheter removal.

Krzysztof Letachowicz1, Tomasz Gołębiowski1, Mariusz Kusztal1, Jan Penar1, Waldemar Letachowicz1, Wacław Weyde1, Marian Klinger1.   

Abstract

INTRODUCTION: Severe, life-threating, complications might occur on dialysis catheter removal.
METHODS: We present a useful technique that may prevent vascular air embolism and severe bleeding.
RESULTS: The suture is placed around the catheter and tied over previous tract just after device removal.
CONCLUSIONS: Applying a compressing suture to the tract left after removal of a tunnelled haemodialysis catheter is a simple manoeuvre that could prevent severe complication.

Entities:  

Mesh:

Year:  2016        PMID: 27834456     DOI: 10.5301/jva.5000620

Source DB:  PubMed          Journal:  J Vasc Access        ISSN: 1129-7298            Impact factor:   2.283


  2 in total

Review 1.  Venous air embolism related to the use of central catheters revisited: with emphasis on dialysis catheters.

Authors:  Steve Siu-Man Wong; Hau C Kwaan; Todd S Ing
Journal:  Clin Kidney J       Date:  2017-07-28

2.  Tunnelled Haemodialysis Catheter Removal: An Underappreciated Problem, Not Always Simple and Safe.

Authors:  Tomasz Porazko; Jacek Hobot; Zbigniew Ziembik; Marian Klinger
Journal:  Int J Environ Res Public Health       Date:  2020-04-27       Impact factor: 3.390

  2 in total