Literature DB >> 27832988

Fourteen-year outcomes of abdominal aortic endovascular repair with the Zenith stent graft.

Fabio Verzini1, Lydia Romano2, Gianbattista Parlani2, Giacomo Isernia2, Gioele Simonte2, Diletta Loschi2, Massimo Lenti2, Piergiorgio Cao3.   

Abstract

OBJECTIVE: Long-term results of abdominal aortic aneurysm (AAA) endovascular repair are affected by graft design renewals that tend to improve the performance of older generation prostheses but usually reset the follow-up times to zero. The present study investigated the long-term outcomes of endovascular AAA repair (EVAR) using the Zenith graft, still in use without major modification, in a single center experience.
METHODS: Between 2000 and 2011, 610 patients underwent elective EVAR using the Zenith endograft (Cook Inc, Bloomington, Ind) and represent the study group. Primary outcomes were overall survival, freedom from AAA rupture, and freedom from AAA-related death. Secondary outcomes included freedom from late (>30 days) reintervention, freedom from late (>30 days) conversion to open repair, freedom from aneurysm sac enlargement >5.0 mm and freedom from EVAR failure, defined as a composite of AAA-related death, AAA rupture, AAA growth >5 mm, and any reintervention.
RESULTS: Mean age was 73.2 years. Mean aneurysm diameter was 55.3 mm. There were five perioperative deaths (0.8%) and three intraoperative conversions. At a mean follow-up of 99.2 (range, 0-175) months, seven AAA ruptures occurred, all fatal except one. Overall survival was 92.8% ± 1.1% at 1 year, 70.1% ± 1.9% at 5 years, 37.8% ± 2.9% at 10 years, and 24 ± 4% at 14 years. Freedom from AAA-rupture was 99.8% ± 0.02 at 1 year (one case), 99.4% ± 0.04 at 5 years (three cases), and 98.1% ± 0.07 at 10 and 14 years. Freedom from late reintervention and conversion was 98% ± 0.6 at 1 year, 87.7% ± 1.5 at 5 years, 75.7% ± 3.2 at 10 years, and 69.9% ± 5.2 at 14 years. Freedom from aneurysm sac growth >5.0 mm was 99.8% at 1 year, 96.6% ± 0.7 at 5 years, 81.0% ± 3.4 at 10 years, and 74.1% ± 5.8% at 14 years. EVAR failure occurred in 132 (21.6%) patients at 14 years. At multivariate analysis, independent predictors of EVAR failure resulted type I and III endoleak (hazard ratio [HR], 6.7; 95% confidence interval [CI], 4.6- 9.7; P < .001], type II endoleak (HR, 2.3; 95% CI, 1.6-3.4; P < .001), and American Society of Anesthesiologists grade 4 (HR, 1.6; 95% CI, 1.0-2.6; P = .034).
CONCLUSIONS: EVAR with Zenith graft represents a safe and durable repair. Risk of rupture and aneurysm-related death is low, whereas overall long-term survival remains poor. Novel endograft models should be tested and evaluated considering that one-fourth of the operated patients will still be alive after 14 years.
Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27832988     DOI: 10.1016/j.jvs.2016.07.117

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  6 in total

1.  Late graft failure is rare after endovascular aneurysm repair using the Zenith stent graft in a cohort of high-risk patients.

Authors:  Joel L Ramirez; Melinda S Schaller; Bian Wu; Linda M Reilly; Timothy A M Chuter; Jade S Hiramoto
Journal:  J Vasc Surg       Date:  2019-05-27       Impact factor: 4.268

2.  Long-term outcomes of endovascular aortic aneurysm repair with the Zenith AAA endovascular graft: a single-center study.

Authors:  Hiroshi Kawamata; Hiroyuki Tajima; Tatsuo Ueda; Hidemasa Saito; Daisuke Yasui; Tadashi Kaneshiro; Naoko Takenoshita; Shouhei Mizushima; Takahiko Mine; Jiro Kurita; Yosuke Ishii; Tetsuro Morota; Takashi Nitta; Yuji Maruyama; Hajime Imura; Dai Nishina; Masahiro Fujii; Ryuzo Bessho
Journal:  Jpn J Radiol       Date:  2019-10-29       Impact factor: 2.374

3.  Clinical evaluation of endovascular repair of abdominal aortic aneurysm based on long-term experiences.

Authors:  Piotr Kulig; Krzysztof Lewandowski; Bogusław Rudel; Maciej Chwała; Marek Piwowarczyk; Wojciech Mrowiecki
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2020-03-27       Impact factor: 1.195

4.  What factors counteract mid-term survival following endovascular repair of abdominal aortic aneurysms?

Authors:  Ertekin Utku Ünal; Hakkı Zafer İscan; Bekir Bogachan Akkaya; İsa Civelek; Mehmet Karahan; Ece Celikten; Göktan Askin; Hayrettin Levent Mavioğlu; Mehmet Ali Özatik
Journal:  Kardiochir Torakochirurgia Pol       Date:  2021-05-15

5.  Single centre experience with Excluder® stent graft; 17-year outcome.

Authors:  Ziga Snoj; Tjasa Tomazin; Vladka Salapura; Dimitrij Kuhelj
Journal:  Radiol Oncol       Date:  2022-04-13       Impact factor: 4.214

6.  Abdominal Aortic Aneurysm: Can the Anaconda™ Custom-Made Device Deliver? An International Perspective.

Authors:  Matti Jubouri; Abedalaziz O Surkhi; Sven Z C P Tan; Damian M Bailey; Ian M Williams; Mohamad Bashir
Journal:  Front Cardiovasc Med       Date:  2022-07-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.