Literature DB >> 27832558

A comparative study of tracheal diameter in Caucasian and Chinese patients.

A Tai1, C Corke2, G M Joynt3, J Griffith4, D Lunn5, Pwy Tong6.   

Abstract

Ethnicity may be considered a factor when considering what size endotracheal tube to insert. In particular it has been suggested that Chinese patients have a smaller tracheal diameter, justifying the selection of smaller endotracheal tubes. We systematically evaluated transverse tracheal diameters in Chinese and Caucasian patients, utilising archived computer tomography images. A convenience sample of 100 Caucasian patients from Australia was compared with 100 Chinese patients from Hong Kong. Patients over 18 years of age who had undergone a computerised tomography scan of the neck and thorax, and also had accurate body height and weight recorded, were studied. The mean transverse diameter of the trachea measured at three levels was similar between the Chinese and Caucasian patients. At the narrowest measurement point, the immediate subcricoid transverse diameter, the unadjusted mean difference between male Chinese and Caucasian patients was small (1 mm, standard deviation 0.83 mm, P=0.01), and similarly small between female Chinese and Caucasian patients (1.5 mm, standard deviation 0.8 mm, P <0.01). Multivariate analysis demonstrated only a small influence related to ethnicity (12% relative contribution to the overall variance [R2] of the model), but substantial influence of height (40%) and sex (41%). Our findings do not support the practice of routinely selecting a smaller endotracheal tube size for Chinese patients on the basis that there is a difference related to the Chinese ethnic phenotype. Considerations regarding choice of endotracheal tube size should rather focus on patient sex and height.

Entities:  

Keywords:  tracheal diameter, patient ethnicity, Chinese

Mesh:

Year:  2016        PMID: 27832558     DOI: 10.1177/0310057X1604400603

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  2 in total

1.  Determining Carina and Clavicular Distance-Dependent Positioning of Endotracheal Tube in Critically Ill Patients: An Artificial Intelligence-Based Approach.

Authors:  Lung-Wen Tsai; Kuo-Ching Yuan; Sen-Kuang Hou; Wei-Lin Wu; Chen-Hao Hsu; Tyng-Luh Liu; Kuang-Min Lee; Chiao-Hsuan Li; Hann-Chyun Chen; Ethan Tu; Rajni Dubey; Chun-Fu Yeh; Ray-Jade Chen
Journal:  Biology (Basel)       Date:  2022-03-23

2.  Two Endotracheal Tubes in One Trachea with a Traumatic Injury.

Authors:  Andrew Winegarner; Harish Lecamwasam; Mark C Kendall; Shyamal Asher
Journal:  Case Rep Anesthesiol       Date:  2021-05-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.