Literature DB >> 27830464

2D to 3D fusion of echocardiography and cardiac CT for TAVR and TAVI image guidance.

Azira Khalil1, Amir Faisal1, Khin Wee Lai1, Siew Cheok Ng1, Yih Miin Liew2.   

Abstract

This study proposed a registration framework to fuse 2D echocardiography images of the aortic valve with preoperative cardiac CT volume. The registration facilitates the fusion of CT and echocardiography to aid the diagnosis of aortic valve diseases and provide surgical guidance during transcatheter aortic valve replacement and implantation. The image registration framework consists of two major steps: temporal synchronization and spatial registration. Temporal synchronization allows time stamping of echocardiography time series data to identify frames that are at similar cardiac phase as the CT volume. Spatial registration is an intensity-based normalized mutual information method applied with pattern search optimization algorithm to produce an interpolated cardiac CT image that matches the echocardiography image. Our proposed registration method has been applied on the short-axis "Mercedes Benz" sign view of the aortic valve and long-axis parasternal view of echocardiography images from ten patients. The accuracy of our fully automated registration method was 0.81 ± 0.08 and 1.30 ± 0.13 mm in terms of Dice coefficient and Hausdorff distance for short-axis aortic valve view registration, whereas for long-axis parasternal view registration it was 0.79 ± 0.02 and 1.19 ± 0.11 mm, respectively. This accuracy is comparable to gold standard manual registration by expert. There was no significant difference in aortic annulus diameter measurement between the automatically and manually registered CT images. Without the use of optical tracking, we have shown the applicability of this technique for effective fusion of echocardiography with preoperative CT volume to potentially facilitate catheter-based surgery.

Entities:  

Keywords:  Cardiovascular; Computed tomography; Echocardiography; Fusion; Image registration

Mesh:

Year:  2016        PMID: 27830464     DOI: 10.1007/s11517-016-1594-6

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  27 in total

1.  Evaluation of motion-correction techniques in cardiac SPECT.

Authors:  M K O'Connor
Journal:  J Nucl Med       Date:  2000-07       Impact factor: 10.057

2.  Cardiology patient pages. Aortic valve disease.

Authors:  Rick A Nishimura
Journal:  Circulation       Date:  2002-08-13       Impact factor: 29.690

3.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery.

Authors:  Martin B Leon; Craig R Smith; Michael Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; David L Brown; Peter C Block; Robert A Guyton; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Pamela S Douglas; John L Petersen; Jodi J Akin; William N Anderson; Duolao Wang; Stuart Pocock
Journal:  N Engl J Med       Date:  2010-09-22       Impact factor: 91.245

4.  Automatic aorta segmentation and valve landmark detection in C-arm CT: application to aortic valve implantation.

Authors:  Yefeng Zheng; Matthias John; Rui Liao; Jan Boese; Uwe Kirschstein; Bogdan Georgescu; S Kevin Zhou; Jörg Kempfert; Thomas Walther; Gernot Brockmann; Dorin Comaniciu
Journal:  Med Image Comput Comput Assist Interv       Date:  2010

5.  Dynamic 2D ultrasound and 3D CT image registration of the beating heart.

Authors:  Xishi Huang; John Moore; Gerard Guiraudon; Douglas L Jones; Daniel Bainbridge; Jing Ren; Terry M Peters
Journal:  IEEE Trans Med Imaging       Date:  2009-01-06       Impact factor: 10.048

6.  Low-Flow, Low-Gradient Severe Aortic Stenosis in the Setting of Constrictive Pericarditis: Clinical Characteristics, Echocardiographic Features, and Outcomes.

Authors:  Michael Y C Tsang; Jin-Oh Choi; Barry A Borlaug; Kevin L Greason; Stephen S Cha; Rick A Nishimura; Jae K Oh
Journal:  Circ Cardiovasc Imaging       Date:  2015-07       Impact factor: 7.792

7.  Segmentation and tracking in echocardiographic sequences: active contours guided by optical flow estimates.

Authors:  I Mikić; S Krucinski; J D Thomas
Journal:  IEEE Trans Med Imaging       Date:  1998-04       Impact factor: 10.048

8.  Correlation of SPECT and PET cardiac images by a surface matching registration technique.

Authors:  M C Gilardi; G Rizzo; A Savi; C Landoni; V Bettinardi; C Rossetti; G Striano; F Fazio
Journal:  Comput Med Imaging Graph       Date:  1998 Sep-Oct       Impact factor: 4.790

9.  Multimodality image registration by maximization of mutual information.

Authors:  F Maes; A Collignon; D Vandermeulen; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

10.  Prevalence and clinical determinants of mitral, tricuspid, and aortic regurgitation (the Framingham Heart Study)

Authors:  J P Singh; J C Evans; D Levy; M G Larson; L A Freed; D L Fuller; B Lehman; E J Benjamin
Journal:  Am J Cardiol       Date:  1999-03-15       Impact factor: 2.778

View more
  5 in total

1.  Multimodality registration of two-dimensional echocardiography and cardiac CT for mitral valve diagnosis and surgical planning.

Authors:  Azira Khalil; Amir Faisal; Siew-Cheok Ng; Yih Miin Liew; Khin Wee Lai
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-19

Review 2.  The Role of Multimodality Imaging in Transcatheter Aortic Valve Replacement.

Authors:  Qi Liu; Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2019-07-19       Impact factor: 2.931

3.  Computational analysis of the effect of mitral and aortic regurgitation on the function of ventricular assist devices using 3D cardiac electromechanical model.

Authors:  Yoo Seok Kim; Ana R Yuniarti; Kwang-Soup Song; Natalia A Trayanova; Eun Bo Shim; Ki Moo Lim
Journal:  Med Biol Eng Comput       Date:  2017-10-28       Impact factor: 2.602

Review 4.  An Overview on Image Registration Techniques for Cardiac Diagnosis and Treatment.

Authors:  Azira Khalil; Siew-Cheok Ng; Yih Miin Liew; Khin Wee Lai
Journal:  Cardiol Res Pract       Date:  2018-08-08       Impact factor: 1.866

5.  Comparative studies of deep learning segmentation models for left ventricle segmentation.

Authors:  Muhammad Ali Shoaib; Khin Wee Lai; Joon Huang Chuah; Yan Chai Hum; Raza Ali; Samiappan Dhanalakshmi; Huanhuan Wang; Xiang Wu
Journal:  Front Public Health       Date:  2022-08-25
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.