A novel electrochemical DNA biosensor has been facilely constructed by in-situ assembly of electroactive 4'-aminobenzo-18-crown-6-copper(II) complex (AbC-Cu2+) on the free terminal of the hairpin-structured molecule beacon. The 3'-SH modified molecule beacon probe was first immobilized on the gold electrode (AuE) surface through self-assembly chemistry of Au-S bond. Then the crow ester of AbC was covalently coupled with 5'-COOH on the molecule beacon, and served as a platform to attach the Cu2+ by coordination with ether bond (-O-) of the crown cycle. Thus, an electroactive molecule beacon-based biosensing interface was constructed. In comparison with conventional methods for preparation of electroactive molecule beacon, the approach presented in this work is much simpler, reagent- and labor-saving. Selectivity study shows that the in-situ fabricated electroactive molecule beacon remains excellent recognition ability of pristine molecule beacon probe to well differentiate various DNA fragments. The target DNA can be quantatively determined over the range from 0.10pM to 0.50nM. The detection limit of 0.060pM was estimated based on signal-to-noise ratio of 3. When the biosensor was applied for the detection cauliflower mosaic virus 35s (CaMV 35s) in soybean extraction samples, satisfactory results are achieved. This work opens a new strategy for facilely fabricating electrochemical sensing interface, which also shows great potential in aptasensor and immurosensor fabrication.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  4′-aminobenzo-18-crown-6; Copper complex; Electrochemical DNA sensor; In-situ modification; Molecule beacon

Mesh:

Substances:

Year:  2016        PMID: 27829553     DOI: 10.1016/j.bios.2016.10.055

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

Review 1.  Evolution of nucleic acids biosensors detection limit III.

Authors:  Yuan Yuan Zhang; François-Xavier Guillon; Sophie Griveau; Fethi Bedioui; Mathieu Lazerges; Cyrine Slim
Journal:  Anal Bioanal Chem       Date:  2021-10-19       Impact factor: 4.142

2.  A Quantitative PCR-Electrochemical Genosensor Test for the Screening of Biotech Crops.

Authors:  Suely Moura-Melo; Rebeca Miranda-Castro; Noemí de-Los-Santos-Álvarez; Arturo J Miranda-Ordieres; José Ribeiro Dos Santos Junior; Rosana A da Silva Fonseca; María Jesús Lobo-Castañón
Journal:  Sensors (Basel)       Date:  2017-04-18       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.