Literature DB >> 27829191

Determination of replicate composite bone material properties using modal analysis.

Steven Leuridan1, Quentin Goossens2, Leonard Pastrav3, Jorg Roosen4, Michiel Mulier5, Kathleen Denis6, Wim Desmet7, Jos Vander Sloten8.   

Abstract

Replicate composite bones are used extensively for in vitro testing of new orthopedic devices. Contrary to tests with cadaveric bone material, which inherently exhibits large variability, they offer a standardized alternative with limited variability. Accurate knowledge of the composite's material properties is important when interpreting in vitro test results and when using them in FE models of biomechanical constructs. The cortical bone analogue material properties of three different fourth-generation composite bone models were determined by updating FE bone models using experimental and numerical modal analyses results. The influence of the cortical bone analogue material model (isotropic or transversely isotropic) and the inter- and intra-specimen variability were assessed. Isotropic cortical bone analogue material models failed to represent the experimental behavior in a satisfactory way even after updating the elastic material constants. When transversely isotropic material models were used, the updating procedure resulted in a reduction of the longitudinal Young's modulus from 16.00GPa before updating to an average of 13.96 GPa after updating. The shear modulus was increased from 3.30GPa to an average value of 3.92GPa. The transverse Young's modulus was lowered from an initial value of 10.00GPa to 9.89GPa. Low inter- and intra-specimen variability was found.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Fourth-generation replicate composite bones; Material parameters updating; Modal analysis

Mesh:

Substances:

Year:  2016        PMID: 27829191     DOI: 10.1016/j.jmbbm.2016.10.018

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  2 in total

1.  Replacement of Destructive Pull-out Test with Modal Analysis in Primary Fixation Stability Assessment of Spinal Pedicle Screw.

Authors:  Mohammadjavad Einafshar; Ata Hashemi; Gerrit Harry van Lenthe
Journal:  Arch Bone Jt Surg       Date:  2022-02

2.  Development of an Instrument to Assess the Stability of Cementless Femoral Implants Using Vibration Analysis During Total Hip Arthroplasty.

Authors:  Steven Leuridan; Quentin Goossens; Leonard Cezar Pastrav; Michiel Mulier; Wim Desmet; Jos Vander Sloten; Kathleen Denis
Journal:  IEEE J Transl Eng Health Med       Date:  2021-11-15       Impact factor: 3.316

  2 in total