Literature DB >> 27825889

Carcinoembryonic antigen detection with "Handing"-controlled fluorescence spectroscopy using a color matrix for point-of-care applications.

Weijian Qin1, Kan Wang2, Kun Xiao1, Yafei Hou1, Wenting Lu3, Hao Xu4, Yan Wo5, Shaoqing Feng5, Daxiang Cui6.   

Abstract

In this study, we developed a power-free, accurate, and portable diagnostic platform called Handing based on embedded technology, which can rapidly detect fluorescent signals from quantum dots (QDs) on lateral flow test strips (LFTSs). The Handing system has three components: a hand-held test terminal, LFTS cartridge, and data server. The hand-held test terminal is the primary system component and it is integrated with tiny components using printed circuit board packaging for image acquisition, processing, and data handling by a specific program. A black smooth shell and three-dimensional printed test cartridge are used to facilitate the portability of the detection terminal, which provides a closed detection process as well as enhancing the anti-interference capacity. The functions of the data server comprise pre-editing, storage, range querying, and sharing with an international network. Multiple hand-held terminal devices can be linked simultaneously to the same data server. In this study, we detected the tumor marker carcinoembryonic antigen (CEA) using the QD-LFTS system, which allowed quantitative analysis in the range of 1-100ng/mL with an ideal detection limit of 0.049ng/mL. Thus, the system is suitable for detecting CEA in the clinically accepted range. We also detected 70 positive and 30 negative serum samples using the Handing system, which exhibited good specificity and sensitivity. Thus, Handing has the capacity for rapid quantitative detection with high stability and repeatability, so it could be used for in vitro diagnostics in the laboratory and in other conditions for various applications, e.g., food evaluation, disease screening, environmental monitoring, and drug testing.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Color matrix; Embedded technology; Hand-held; Lateral flow test strip (LFTS); Quantum dot (QD)

Mesh:

Substances:

Year:  2016        PMID: 27825889     DOI: 10.1016/j.bios.2016.10.052

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Fluorometric nanoprobes for simultaneous aptamer-based detection of carcinoembryonic antigen and prostate specific antigen.

Authors:  Yali Sun; Jianfeng Fan; Linyan Cui; Wei Ke; Fangjie Zheng; Yuan Zhao
Journal:  Mikrochim Acta       Date:  2019-02-02       Impact factor: 5.833

Review 2.  Lateral flow biosensors based on the use of micro- and nanomaterials: a review on recent developments.

Authors:  Yan Huang; Tailin Xu; Wenqian Wang; Yongqiang Wen; Kun Li; Lisheng Qian; Xueji Zhang; Guodong Liu
Journal:  Mikrochim Acta       Date:  2019-12-18       Impact factor: 5.833

Review 3.  Nanozyme-based colorimetric biosensor with a systemic quantification algorithm for noninvasive glucose monitoring.

Authors:  Hee-Jae Jeon; Hyung Shik Kim; Euiheon Chung; Dong Yun Lee
Journal:  Theranostics       Date:  2022-09-07       Impact factor: 11.600

4.  On-Site Detection of Carcinoembryonic Antigen in Human Serum.

Authors:  Tohid Mahmoudi; Mohammad Pourhassan-Moghaddam; Behnaz Shirdel; Behzad Baradaran; Eden Morales-Narváez; Hamed Golmohammadi
Journal:  Biosensors (Basel)       Date:  2021-10-14

Review 5.  Determination of Drugs in Clinical Trials: Current Status and Outlook.

Authors:  Babak Tavana; Aicheng Chen
Journal:  Sensors (Basel)       Date:  2022-02-18       Impact factor: 3.576

6.  Smartphone-Based Dual-Modality Imaging System for Quantitative Detection of Color or Fluorescent Lateral Flow Immunochromatographic Strips.

Authors:  Yafei Hou; Kan Wang; Kun Xiao; Weijian Qin; Wenting Lu; Wei Tao; Daxiang Cui
Journal:  Nanoscale Res Lett       Date:  2017-04-21       Impact factor: 4.703

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.