Literature DB >> 27825884

White blood cell counting on smartphone paper electrochemical sensor.

Xinhao Wang1, Guohong Lin2, Guangzhe Cui3, Xiangfei Zhou1, Gang Logan Liu4.   

Abstract

White blood cell (WBC) analysis provides rich information in rapid diagnosis of acute bacterial and viral infections as well as chronic disease management. For patients with immune deficiency or leukemia WBC should be persistently monitored. Current WBC counting method relies on bulky instrument and trained personnel and is time consuming. Rapid, low-cost and portable solution is in highly demand for point of care test. Here we demonstrate a label-free smartphone based electrochemical WBC counting device on microporous paper with patterned gold microelectrodes. WBC separated from whole blood was trapped by the paper with microelectrodes. WBC trapped on the paper leads to the ion diffusion blockage on microelectrodes, therefore cell concentration is determined by peak current on the microelectrodes measured by a differential pulse voltammeter and the quantitative results are collected by a smartphone wirelessly within 1min. We are able to rapidly quantify WBC concentrations covering the common physiological and pathological range (200-20000μL-1) with only 10μL sample and high repeatability as low as 10% in CoV (Coefficient of Variation). The unique smartphone paper electrochemical sensor ensures fast cell quantification to achieve rapid and low-cost WBC analysis at the point-of-care under resource limited conditions.
Copyright © 2016. Published by Elsevier B.V.

Entities:  

Keywords:  Diffusion impedance; Label-free; Paper electrochemical; Point-of-care; Smartphone; White blood cell

Mesh:

Year:  2016        PMID: 27825884     DOI: 10.1016/j.bios.2016.10.017

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Biosensors for Personal Mobile Health: A System Architecture Perspective.

Authors:  Siddarth Arumugam; David A M Colburn; Samuel K Sia
Journal:  Adv Mater Technol       Date:  2019-11-20

2.  Smartphone-Based Electrochemical Potentiostat Detection System Using PEDOT: PSS/Chitosan/Graphene Modified Screen-Printed Electrodes for Dopamine Detection.

Authors:  Xiaoyan Shen; Feng Ju; Guicai Li; Lei Ma
Journal:  Sensors (Basel)       Date:  2020-05-14       Impact factor: 3.576

Review 3.  Microfluidic and Paper-Based Devices for Disease Detection and Diagnostic Research.

Authors:  Joshua M Campbell; Joseph B Balhoff; Grant M Landwehr; Sharif M Rahman; Manibarathi Vaithiyanathan; Adam T Melvin
Journal:  Int J Mol Sci       Date:  2018-09-12       Impact factor: 5.923

Review 4.  Electrochemical sensing: A prognostic tool in the fight against COVID-19.

Authors:  Sharda Kotru; Martin Klimuntowski; Hashim Ridha; Zakir Uddin; Ali A Askhar; Gurmit Singh; Matiar M R Howlader
Journal:  Trends Analyt Chem       Date:  2021-01-23       Impact factor: 14.908

5.  Study on perinatal-related factors of maternity and newborn in parturients with intrapartum fever in part of Eastern China: A cross-sectional study.

Authors:  Yuru Fan; Chong Fan; Pengyuan Mao; Can Rui; Xinyan Wang; Wenwen Hou; Ting Luan; Zhiyong Dong; Ping Li; Shanwu Feng; Xin Zeng
Journal:  J Clin Lab Anal       Date:  2021-11-16       Impact factor: 2.352

Review 6.  Virus Detection: From State-of-the-Art Laboratories to Smartphone-Based Point-of-Care Testing.

Authors:  Meng Xiao; Feng Tian; Xin Liu; Qiaoqiao Zhou; Jiangfei Pan; Zhaofan Luo; Mo Yang; Changqing Yi
Journal:  Adv Sci (Weinh)       Date:  2022-04-07       Impact factor: 17.521

  6 in total