Literature DB >> 27825650

Development of a multi-matrix LC-MS/MS method for urea quantitation and its application in human respiratory disease studies.

Jianshuang Wang1, Yang Gao2, Drew W Dorshorst2, Fang Cai3, Meire Bremer3, Dennis Milanowski2, Tracy L Staton3, Stephanie S Cape2, Brian Dean4, Xiao Ding4.   

Abstract

In human respiratory disease studies, liquid samples such as nasal secretion (NS), lung epithelial lining fluid (ELF), or upper airway mucosal lining fluid (MLF) are frequently collected, but their volumes often remain unknown. The lack of volume information makes it hard to estimate the actual concentration of recovered active pharmaceutical ingredient or biomarkers. Urea has been proposed to serve as a sample volume marker because it can freely diffuse through most body compartments and is less affected by disease states. Here, we report an easy and reliable LC-MS/MS method for cross-matrix measurement of urea in serum, plasma, universal transfer medium (UTM), synthetic absorptive matrix elution buffer 1 (SAMe1) and synthetic absorptive matrix elution buffer 2 (SAMe2) which are commonly sampled in human respiratory disease studies. The method uses two stable-isotope-labeled urea isotopologues, [15N2]-urea and [13C,15N2]-urea, as the surrogate analyte and the internal standard, respectively. This approach provides the best measurement consistency across different matrices. The analyte extraction was individually optimized in each matrix. Specifically in UTM, SAMe1 and SAMe2, the unique salting-out assisted liquid-liquid extraction (SALLE) not only dramatically reduces the matrix interferences but also improves the assay recovery. The use of an HILIC column largely increases the analyte retention. The typical run time is 3.6min which allows for high throughput analysis. Copyright Â
© 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bioanalysis; LC–MS/MS; Respiratory disease; Urea; Volume normalization

Mesh:

Substances:

Year:  2016        PMID: 27825650     DOI: 10.1016/j.jpba.2016.11.001

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  1 in total

1.  Passive sweat collection and colorimetric analysis of biomarkers relevant to kidney disorders using a soft microfluidic system.

Authors:  Yi Zhang; Hexia Guo; Sung Bong Kim; Yixin Wu; Diana Ostojich; Sook Hyeon Park; Xueju Wang; Zhengyan Weng; Rui Li; Amay J Bandodkar; Yurina Sekine; Jungil Choi; Shuai Xu; Susan Quaggin; Roozbeh Ghaffari; John A Rogers
Journal:  Lab Chip       Date:  2019-04-23       Impact factor: 6.799

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.