Literature DB >> 27824215

Optimized phase gradient measurements and phase-amplitude interplay in optical coherence elastography.

Vladimir Y Zaitsev1, Alexander L Matveyev1, Lev A Matveev1, Grigory V Gelikonov1, Aleksandr A Sovetsky2, Alex Vitkin3.   

Abstract

In compressional optical coherence elastography, phase-variation gradients are used for estimating quasistatic strains created in tissue. Using reference and deformed optical coherence tomography (OCT) scans, one typically compares phases from pixels with the same coordinates in both scans. Usually, this limits the allowable strains to fairly small values <10?4 to 10?3, with the caveat that such weak phase gradients may become corrupted by stronger measurement noises. Here, we extend the OCT phase-resolved elastographic methodology by (1) showing that an order of magnitude greater strains can significantly increase the accuracy of derived phase-gradient differences, while also avoiding error-phone phase-unwrapping procedures and minimizing the influence of decorrelation noise caused by suprapixel displacements, (2) discussing the appearance of artifactual stiff inclusions in resultant OCT elastograms in the vicinity of bright scatterers due to the amplitude-phase interplay in phase-variation measurements, and (3) deriving/evaluating methods of phase-gradient estimation that can outperform conventionally used least-square gradient fitting. We present analytical arguments, numerical simulations, and experimental examples to demonstrate the advantages of the proposed optimized phase-variation methodology.

Mesh:

Year:  2016        PMID: 27824215     DOI: 10.1117/1.JBO.21.11.116005

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  11 in total

1.  Spatial coordinate corrected motion tracking for optical coherence elastography.

Authors:  Xuan Liu; Basil Hubbi; Xianlian Zhou
Journal:  Biomed Opt Express       Date:  2019-11-06       Impact factor: 3.732

2.  Simulating scan formation in multimodal optical coherence tomography: angular-spectrum formulation based on ballistic scattering of arbitrary-form beams.

Authors:  Alexander L Matveyev; Lev A Matveev; Aleksandr A Moiseev; Alexander A Sovetsky; Grigory V Gelikonov; Vladimir Y Zaitsev
Journal:  Biomed Opt Express       Date:  2021-11-16       Impact factor: 3.732

3.  Compression optical coherence elastography versus strain ultrasound elastography for breast cancer detection and differentiation: pilot study.

Authors:  Ekaterina V Gubarkova; Aleksander A Sovetsky; Dmitry A Vorontsov; Pavel A Buday; Marina A Sirotkina; Anton A Plekhanov; Sergey S Kuznetsov; Aleksander L Matveyev; Lev A Matveev; Sergey V Gamayunov; Alexey Y Vorontsov; Vladimir Y Zaitsev; Natalia D Gladkova
Journal:  Biomed Opt Express       Date:  2022-04-21       Impact factor: 3.562

4.  Analysis of strain estimation methods in phase-sensitive compression optical coherence elastography.

Authors:  Jiayue Li; Ewelina Pijewska; Qi Fang; Maciej Szkulmowski; Brendan F Kennedy
Journal:  Biomed Opt Express       Date:  2022-03-18       Impact factor: 3.562

5.  Nonlinear Elasticity Assessment with Optical Coherence Elastography for High-Selectivity Differentiation of Breast Cancer Tissues.

Authors:  Ekaterina V Gubarkova; Aleksander A Sovetsky; Lev A Matveev; Aleksander L Matveyev; Dmitry A Vorontsov; Anton A Plekhanov; Sergey S Kuznetsov; Sergey V Gamayunov; Alexey Y Vorontsov; Marina A Sirotkina; Natalia D Gladkova; Vladimir Y Zaitsev
Journal:  Materials (Basel)       Date:  2022-05-05       Impact factor: 3.748

6.  In vivo assessment of functional and morphological alterations in tumors under treatment using OCT-angiography combined with OCT-elastography.

Authors:  Marina A Sirotkina; Ekaterina V Gubarkova; Anton A Plekhanov; Alexander A Sovetsky; Vadim V Elagin; Alexander L Matveyev; Lev A Matveev; Sergey S Kuznetsov; Elena V Zagaynova; Natalia D Gladkova; Vladimir Y Zaitsev
Journal:  Biomed Opt Express       Date:  2020-02-13       Impact factor: 3.732

7.  Deformation velocity imaging using optical coherence tomography and its applications to the cornea.

Authors:  Samuel Lawman; Peter W Madden; Vito Romano; Yue Dong; Sharon Mason; Bryan M Williams; Stephen B Kaye; Colin E Willoughby; Simon P Harding; Yao-Chun Shen; Yalin Zheng
Journal:  Biomed Opt Express       Date:  2017-11-13       Impact factor: 3.732

8.  Diagnostic Accuracy of Cross-Polarization OCT and OCT-Elastography for Differentiation of Breast Cancer Subtypes: Comparative Study.

Authors:  Ekaterina V Gubarkova; Elena B Kiseleva; Marina A Sirotkina; Dmitry A Vorontsov; Ksenia A Achkasova; Sergey S Kuznetsov; Konstantin S Yashin; Aleksander L Matveyev; Aleksander A Sovetsky; Lev A Matveev; Anton A Plekhanov; Alexey Y Vorontsov; Vladimir Y Zaitsev; Natalia D Gladkova
Journal:  Diagnostics (Basel)       Date:  2020-11-24

9.  Histological validation of in vivo assessment of cancer tissue inhomogeneity and automated morphological segmentation enabled by Optical Coherence Elastography.

Authors:  Natalia D Gladkova; Vladimir Y Zaitsev; Anton A Plekhanov; Marina A Sirotkina; Alexander A Sovetsky; Ekaterina V Gubarkova; Sergey S Kuznetsov; Alexander L Matveyev; Lev A Matveev; Elena V Zagaynova
Journal:  Sci Rep       Date:  2020-07-16       Impact factor: 4.379

10.  Optical Coherence Elastography-Based Corneal Strain Imaging During Low-Amplitude Intraocular Pressure Modulation.

Authors:  Sabine Kling; Hossein Khodadadi; Orcun Goksel
Journal:  Front Bioeng Biotechnol       Date:  2020-01-31