Literature DB >> 27823950

The 99th percentile values of six cardiac troponin assays established for a reference population using strict selection criteria.

Dae-Hyun Ko1, Tae-Dong Jeong2, Eun-Jung Cho3, Jinsook Lim4, Misuk Ji5, Kyunghoon Lee6, Woochang Lee3, Yeo-Min Yun5, Sail Chun3, Junghan Song6, Kye-Chul Kwon4, Won-Ki Min7.   

Abstract

BACKGROUND: Since the 99th percentile reference limit for cardiac troponin (Tn) can vary depending on the reference population, Sandoval et al. published systematic selection criteria. In this study, these systematic criteria were applied for the first time to obtain the 99th percentile reference limits for 6 Tn tests.
METHODS: The reference population was selected in accordance with the systematic criteria, and reference limits were set with respect to the six types of Tn assays. The coefficient of variation (CV) at the reference limit was determined using 3-4 concentrations of frozen serum.
RESULTS: In total, 641 South Koreans (303 males, 338 females) were selected as the reference population. The 99th percentile reference limit of Tn in the six assays ranged from 13.4 to 34.2pg/ml. The measurable fractions among the reference population ranged from 1.3% to 80.5%. The CVs at the reference limit ranged from 5.3% to 43.0%, and three were <10%.
CONCLUSIONS: In this study, a reference population was selected for the first time in accordance with the systematic criteria of Sandoval et al., and the reference limit for South Koreans was established. The values obtained in this study are different from those proposed by manufacturers, which confirms the importance of having a reference population. Four out of six assays did not fulfill the criteria for high-sensitivity tests.
Copyright © 2016 Elsevier B.V. All rights reserved.

Keywords:  99th percentile; Reference population; South Korean; Troponin

Mesh:

Substances:

Year:  2016        PMID: 27823950     DOI: 10.1016/j.cca.2016.11.004

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  3 in total

1.  Frequency histograms of three high-sensitivity cardiac troponin assays in a reference population.

Authors:  Hanwool Cho; Hyunjung Kim; Jehoon Lee; Soo-Young Kim; Hae Kyung Lee; Hi Jeong Kwon; Yeongsic Kim
Journal:  J Clin Lab Anal       Date:  2022-04-20       Impact factor: 3.124

2.  Determination of high-sensitivity cardiac troponin T upper reference limits under the improved selection criteria in a Chinese population.

Authors:  Xin Zhang; Xiaoxu Han; Min Zhao; Runqing Mu; Shuo Wang; Ke Yun; Hong Shang
Journal:  J Clin Lab Anal       Date:  2019-08-16       Impact factor: 2.352

3.  Effect of Outlier Elimination on the 99th Percentile Upper Reference Limits of High-Sensitivity Cardiac Troponin I Assays Based on a Strictly Selected Healthy Reference Population.

Authors:  Sunyoung Ahn; Hyun-Ki Kim; Woochang Lee; Sail Chun; Won-Ki Min
Journal:  Ann Lab Med       Date:  2022-05-01       Impact factor: 3.464

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.