A non-ionizing technique for three-dimensional measurement of the lumbar spine.

Terry K Koo1, Wingchi Edmund Kwok2.   

Abstract

Comprehensive assessments of scoliotic deformity and spinal instability require repetitive three-dimensional (3D) measurements of motion segments at different functional postures. However, accurate 3D measurement of the spine is a challenging task. In this paper, we present a novel, non-invasive, non-ionizing technique to quantify 3D poses of lumbar motion segments in terms of clinically meaningful anatomical coordinates. The technique used ultra-short echo time (UTE) magnetic resonance (MR) images to construct subject-specific geometrical models of individual vertebrae and registered them with 3D ultrasound dataset acquired during pose measurements. A hierarchical registration approach was used to minimize the detrimental effects of speckle noise and artifacts within soft tissues on registration accuracy. The technique was validated using a human dry bone specimen as well as a fresh porcine cadaver. Registration errors were determined by comparing with a gold standard fiducial-based registration. Results showed that the technique is accurate and reliable with bias in sub-degree and sub-millimeter level (except for the flexion-extension of the porcine cadaver experiment, which was -1.74°), and average precision of 1.11° in rotation and 0.86mm in position for the human dry bone experiment, and 1.26° and 1.23mm for the porcine cadaver experiment. Given its non-ionizing nature, the UTE MR-ultrasound registration technique is particularly useful for repeated measurements and longitudinal follow-up. With further refinement and validation, it could be a powerful tool for 3D spinal assessment.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Lumbar spine; Magnetic resonance imaging; Registration; Segmental kinematics; Ultrasound

Mesh:

Year:  2016        PMID: 27823804     DOI: 10.1016/j.jbiomech.2016.10.048

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  Zero TE MRI for Craniofacial Bone Imaging.

Authors:  A Lu; K R Gorny; M-L Ho
Journal:  AJNR Am J Neuroradiol       Date:  2019-09       Impact factor: 3.825

2.  Relationship between Posture and Non-Contact Lower Limb Injury in Young Male Amateur Football Players: A Prospective Cohort Study.

Authors:  Suzanne J Snodgrass; Kathleen E Ryan; Andrew Miller; Daphne James; Robin Callister
Journal:  Int J Environ Res Public Health       Date:  2021-06-14       Impact factor: 3.390

3.  3D ultrasound navigation system for screw insertion in posterior spine surgery: a phantom study.

Authors:  Andrew Chan; Eric Parent; Jim Mahood; Edmond Lou
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-11-02       Impact factor: 2.924

4.  Actuator-Assisted Calibration of Freehand 3D Ultrasound System.

Authors:  Terry K Koo; Nathaniel Silvia
Journal:  J Healthc Eng       Date:  2018-05-02       Impact factor: 2.682

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.