Literature DB >> 27820694

Degradation Potential of Bulk Versus Incrementally Applied and Indirect Composites: Color, Microhardness, and Surface Deterioration.

M El Gezawi, D Kaisarly, H Al-Saleh, A ArRejaie, F Al-Harbi, K H Kunzelmann.   

Abstract

This study investigated the color stability and microhardness of five composites exposed to four beverages with different pH values. Composite discs were produced (n=10); Filtek Z250 (3M ESPE) and Filtek P90 (3M ESPE) were applied in two layers (2 mm, 20 seconds), and Tetric N-Ceram Bulk Fill (TetricBF, Ivoclar Vivadent) and SonicFill (Kerr) were applied in bulk (4 mm) and then light cured (40 seconds, Ortholux-LED, 1600 mW/cm2). Indirect composite Sinfony (3M ESPE) was applied in two layers (2 mm) and cured (Visio system, 3M ESPE). The specimens were polished and tested for color stability; ΔE was calculated using spectrophotometer readings. Vickers microhardness (50 g, dwell time=45 seconds) was assessed on the top and bottom surfaces at baseline, 40 days of storage, subsequent repolishing, and 60 days of immersion in distilled water (pH=7.0), Coca-Cola (pH=2.3), orange juice (pH=3.75), or anise (pH=8.5) using scanning electron microscopy (SEM). The materials had similar ΔE values (40 days, p>0.05), but TetricBF had a significantly greater ΔE than P90 or SF (40 days). The ΔE was less for P90 and TetricBF than for Z250, SonicFill, and Sinfony (60 days). Repolishing and further immersion significantly affected the ΔE (p<0.05) except for P90. All composites had significantly different top vs bottom baseline microhardnesses. This was insignificant for the Z250/water, P90/orange juice (40 days), and Sinfony groups (40 and 60 days). Immersion produced variable time-dependent deterioration of microhardness in all groups. Multivariate repeated measures analysis of variance with post hoc Bonferroni tests were used to compare the results. ΔE and microhardness changes were significantly inversely correlated at 40 days, but this relationship was insignificant at 60 days (Pearson test). SEM showed degradation (40 days) that worsened (60 days). Bulk-fill composites differ regarding color-stability and top-to-bottom microhardness changes compared with those of other composites. P90 showed better surface degradation resistance. In conclusion, bulk-fill composites are not promising alternatives to incremental and indirect composites regarding biodegradation.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27820694     DOI: 10.2341/15-195-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  8 in total

1.  Surface quality and color stability of posterior composites in acidic beverages.

Authors:  Chappidi M Meenakshi; Kantheti Sirisha
Journal:  J Conserv Dent       Date:  2020-10-10

2.  Effects of Fibers on Color and Translucency Changes of Bulk-Fill and Anterior Composites after Accelerated Aging.

Authors:  Ali Riza Tuncdemir; Mehmet Esad Güven
Journal:  Biomed Res Int       Date:  2018-01-28       Impact factor: 3.411

3.  Impact of dietary solvents on flexural properties of bulk-fill composites.

Authors:  Ahmed Hesham Eweis; Adrian U-Jin Yap; Noor Azlin Yahya
Journal:  Saudi Dent J       Date:  2018-05-05

4.  Four-Year Follow-up of Increased Vertical Dimension of Occlusion using Resin Composites.

Authors:  Cendrella Assaf; Jean Claude Fahd; Joseph Sabbagh
Journal:  J Int Soc Prev Community Dent       Date:  2018-10-08

5.  Mechanical Degradation of Different Classes of Composite Resins Aged in Water, Air, and Oil.

Authors:  Weber Adad Ricci; Priscila Alfano; Saulo Pamato; Carlos Alberto Dos Santos Cruz; Jefferson Ricardo Pereira
Journal:  Biomed Res Int       Date:  2019-01-09       Impact factor: 3.411

6.  Toward a Clinically Reliable Class II Resin Composite Restoration: A Cross-Sectional Study into the Current Clinical Practice among Dentists in Saudi Arabia.

Authors:  Rasha AlSheikh; Khalid S Almulhim; Moamen Abdulkader; Rasha Haridy; Amr S Bugshan; Rand Aldamanhouri; Moataz Elgezawi
Journal:  Int J Dent       Date:  2022-08-02

Review 7.  Ageing of Dental Composites Based on Methacrylate Resins-A Critical Review of the Causes and Method of Assessment.

Authors:  Agata Szczesio-Wlodarczyk; Jerzy Sokolowski; Joanna Kleczewska; Kinga Bociong
Journal:  Polymers (Basel)       Date:  2020-04-10       Impact factor: 4.329

8.  Shrinkage vectors in flowable bulk-fill and conventional composites: bulk versus incremental application.

Authors:  Dalia Kaisarly; Moataz El Gezawi; Andreas Keßler; Peter Rösch; Karl-Heinz Kunzelmann
Journal:  Clin Oral Investig       Date:  2020-07-11       Impact factor: 3.573

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.