Literature DB >> 27818307

Hemocompatibility studies on a degradable polar hydrophobic ionic polyurethane (D-PHI).

Kathryne S Brockman1, Jayachandran N Kizhakkedathu2, J Paul Santerre3.   

Abstract

Biomaterial blood compatibility is a complex process that involves four key pathways, including the coagulation cascade, the complement system, platelets, and leukocytes. While many studies have addressed the initial contact of blood with homopolymeric (e.g. Teflon) or simple copolymeric (e.g. Dacron) biomaterials, relatively less attention has been given to investigating blood coagulation with respect to complex copolymeric systems containing well defined and diverse function. The current study sought to assess the hemocompatibility of a complex polyurethane (PU) containing a unique combination of polar, hydrophobic, and ionic domains (D-PHI). This included a whole blood (WB) study, followed by tests on the intrinsic and extrinsic coagulation pathways, complement activation, platelet activation, and an assessment of the effect of leukocytes on platelet-biomaterial interactions. A small increase in blood clot formation was observed on D-PHI in WB; however, there was no significant increase in clotting via the intrinsic coagulation cascade. No significant increase in platelet adhesion and only a very slight increase in platelet activation were observed in comparison to albumin-coated substrates (negative control). D-PHI showed mild complement activation and increased initiation of the extrinsic pathway of coagulation, along with the observation that leukocytes were important in mediating platelet-biomaterial interactions. It is proposed that complement is responsible for activating coagulation by inciting leukocytes to generate tissue factor (TF), which causes extrinsic pathway activation. This low level of blood clotting on D-PHI's surface may be necessary for the beneficial wound healing of vascular constructs that has been previously reported for this material. STATEMENT OF SIGNIFICANCE: Understanding the hemocompatibility of devices intended for blood-contacting applications is important for predicting device failure. Hemocompatibility is a complex parameter (affected by at least four different mechanisms) that measures the level of thrombus generation and immune system activation resulting from blood-biomaterial contact. The complexity of hemocompatibility implies that homopolymers are unlikely to solve the clotting challenges that face most biomaterials. Diversity in surface chemistry (containing hydrophobic, ionic, and polar domains) obtained from engineered polyurethanes can lead to favourable interactions with blood. The current research considered the effect of a highly functionalized polyurethane biomaterial on all four mechanisms in order to provide a comprehensive in vitro measure of the hemocompatibility of this unique material and the important mechanisms at play.
Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biomaterials; Complement activation; Leukocytes; Platelets; Polyurethane; Thrombosis

Mesh:

Substances:

Year:  2016        PMID: 27818307     DOI: 10.1016/j.actbio.2016.11.005

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  2 in total

1.  Development and Characterization of Acellular Caprine Choncal Cartilage Matrix for Tissue Engineering Applications.

Authors:  Piyali Das; Kanike Rajesh; V Lalzawmliana; K Bavya Devi; Piyali Basak; Debrupa Lahiri; Biswanath Kundu; Mangal Roy; Samit Kumar Nandi
Journal:  Cartilage       Date:  2019-06-19       Impact factor: 3.117

2.  Facile Method for Surface-Grafted Chitooligosaccharide on Medical Segmented Poly(ester-urethane) Film to Improve Surface Biocompatibility.

Authors:  Yifan Liu; Zhengqi Liu; Ya Gao; Weiwei Gao; Zhaosheng Hou; Yuzheng Zhu
Journal:  Membranes (Basel)       Date:  2021-01-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.