PURPOSE: To compare the safety and efficacy profile after combined micro-incision cataract surgery (MICS) and micro-invasive glaucoma surgery (MIGS) with the ab interno trabeculectomy (Trabectome®) in one eye versus two iStent® inject devices in the contralateral eye in patients with open-angle glaucoma (OAG) and cataract. METHODS: This retrospective, intraindividual eye comparison study included 27 patients (54 eyes) who were treated with combined MICS and ab interno trabeculectomy (group I, Trabectome®) in one eye and two iStent® inject devices (group II, GTS 400) in the fellow eye. Primary outcome measures included intraocular pressure (IOP) and glaucoma medication after 6 weeks, 3, 6, and 12 months follow-up. Secondary outcome measures were number of postoperative interventions, complications, and best-corrected visual acuity (BCVA). RESULTS: Mean preoperative IOP decreased from 22.3 ± 3.7 mmHg in group I and 21.3 ± 4.1 mmHg in group II to 15.6 ± 3.6 mmHg for Trabectome (p < 0.001) and 14.0 ± 2.3 mmHg for iStent inject (p < 0.001) at 12 months after surgery without a significant difference between the two groups (p > 0.05). No vision-threatening complications such as choroidal effusion, choroidal hemorrhage, or infection occurred. In each group trabeculectomy had to be performed in two eyes due to insufficient IOP lowering effect. CONCLUSIONS: Ab interno trabeculectomy and iStent® inject were both effective in lowering IOP with a favourable and comparable safety profile in an intraindividual comparative study over a 12-months follow-up in OAG. However, longer follow-up of these patients will be necessary to determine long-term outcomes and to evaluate significant differences.
PURPOSE: To compare the safety and efficacy profile after combined micro-incision cataract surgery (MICS) and micro-invasive glaucoma surgery (MIGS) with the ab interno trabeculectomy (Trabectome®) in one eye versus two iStent® inject devices in the contralateral eye in patients with open-angle glaucoma (OAG) and cataract. METHODS: This retrospective, intraindividual eye comparison study included 27 patients (54 eyes) who were treated with combined MICS and ab interno trabeculectomy (group I, Trabectome®) in one eye and two iStent® inject devices (group II, GTS 400) in the fellow eye. Primary outcome measures included intraocular pressure (IOP) and glaucoma medication after 6 weeks, 3, 6, and 12 months follow-up. Secondary outcome measures were number of postoperative interventions, complications, and best-corrected visual acuity (BCVA). RESULTS: Mean preoperative IOP decreased from 22.3 ± 3.7 mmHg in group I and 21.3 ± 4.1 mmHg in group II to 15.6 ± 3.6 mmHg for Trabectome (p < 0.001) and 14.0 ± 2.3 mmHg for iStent inject (p < 0.001) at 12 months after surgery without a significant difference between the two groups (p > 0.05). No vision-threatening complications such as choroidal effusion, choroidal hemorrhage, or infection occurred. In each group trabeculectomy had to be performed in two eyes due to insufficient IOP lowering effect. CONCLUSIONS: Ab interno trabeculectomy and iStent® inject were both effective in lowering IOP with a favourable and comparable safety profile in an intraindividual comparative study over a 12-months follow-up in OAG. However, longer follow-up of these patients will be necessary to determine long-term outcomes and to evaluate significant differences.
Entities:
Keywords:
MIGS; Trabectome; Trabecular micro-bypass; ab interno trabeculectomy; iStent inject
Authors: Thomas W Samuelson; L Jay Katz; Jeffrey M Wells; Yi-Jing Duh; Jane Ellen Giamporcaro Journal: Ophthalmology Date: 2010-09-15 Impact factor: 12.079
Authors: Monali S Malvankar-Mehta; Yiannis Iordanous; Yufeng Nancy Chen; Wan Wendy Wang; Sangita Shantilal Patel; John Costella; Cindy M L Hutnik Journal: PLoS One Date: 2015-07-06 Impact factor: 3.240
Authors: Antonio M Fea; Jose I Belda; Marek Rękas; Anselm Jünemann; Lydia Chang; Luis Pablo; Lilit Voskanyan; L Jay Katz Journal: Clin Ophthalmol Date: 2014-05-07