Literature DB >> 27814283

A novel two-dimensional quantitative shear wave elastography to make differential diagnosis of breast lesions: Comprehensive evaluation and influencing factors.

Ming-Hua Yao, Rong Wu, Guang Xu, Li-Xia Zhao, Hui Liu, Huan Pu, Yan Fang.   

Abstract

BACKGROUND: Virtual touch imaging quantification (VTIQ), a form of shear wave elastography, may help in the diagnosis of breast lesions.
OBJECTIVE: We aimed to evaluate the diagnostic performance of combined VTIQ and conventional ultrasound (US), and assess the factors influencing VTIQ measurement.
METHODS: From September 2014 to December 2014, 162 patients with breast lesions were examined by US and VTIQ to assess shear wave speed (SWS) and morphological characteristics (lesion shape, orientation, margin and echo pattern). The sensitivity, specificity and accuracy of VTIQ, US and VTIQ+US for the diagnosis of breast lesions was evaluated in comparison to pathological results. Factors influencing deviations in SWS measurements were assessed by logistic regression.
RESULTS: The SWS cut-off between malignant and benign lesions was 3.73 m/s. The sensitivity, specificity and accuracy were: 98.07%, 55.96%, and 69.57% for US; 76.92%, 78.89% and 78.26% for VTIQ; and 98.07%, 84.40% and 88.82% for US+VTIQ. The two factors that influenced the SWS results were the lesion margin (odds ratio [OR], 16.363; 95% confidence interval [CI], 3.220-29.020) and vascularity (OR, 6.712; 95% CI, 1.358-9.072).
CONCLUSIONS: The lesion margin and vascularity could affect the measurement of SWS as well as the experience of examiner. However, VTIQ is still a reliable method that provides valuable information in the differential diagnosis of breast lesions, and may reduce unnecessary biopsies.

Entities:  

Keywords:  Elastography; VTIQ; breast cancer; ultrasound

Mesh:

Year:  2016        PMID: 27814283     DOI: 10.3233/CH-16188

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  4 in total

1.  The value of virtual touch tissue imaging quantification in the differential diagnosis between benign and malignant breast lesions.

Authors:  Wen-Tao Kong; Wei-Jun Zhou; Yin Wang; Xiao-Min Zhuang; Min Wu
Journal:  J Med Ultrason (2001)       Date:  2019-05-17       Impact factor: 1.314

2.  VTIQ evaluates antitumor effects of NET-1 siRNA by UTMD in HCC xenograft models.

Authors:  Xitian Liang; Bolin Wu; Haitao Shang; Xue Han; Hui Jing; Yixin Sun; Wen Cheng
Journal:  Oncol Lett       Date:  2018-06-19       Impact factor: 2.967

Review 3.  New diagnostic tools for breast cancer.

Authors:  Pascal A T Baltzer; Panagiotis Kapetas; Maria Adele Marino; Paola Clauser
Journal:  Memo       Date:  2017-06-28

4.  Value of shear wave arrival time contour display in shear wave elastography for breast masses diagnosis.

Authors:  Bang-Guo Zhou; Dan Wang; Wei-Wei Ren; Xiao-Long Li; Ya-Ping He; Bo-Ji Liu; Qiao Wang; Shi-Gao Chen; Azra Alizad; Hui-Xiong Xu
Journal:  Sci Rep       Date:  2017-08-01       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.