Literature DB >> 27813213

Investigation to test potential stereolithography materials for development of an in vitro root canal model.

Saifalarab A Mohmmed1, Morgana E Vianna2, Stephen T Hilton3, David R Boniface4, Yuan-Ling Ng5, Jonathan C Knowles1.   

Abstract

The aims were to compare the physico-chemical properties (zeta-potential, wettability, surface free energy) of stereolithography materials (STL) (Photopolymer, Accura) to dentine and to evaluate the potential of each material to develop Enterococcus faecalis biofilm on their respective surfaces. Eighteen samples of each test material (Photopolymer, Accura, dentine) were employed (total n = 54) and sectioned to 1 mm squares (5 mm x 5 mm) (n = 15) or ground into a powder to measure zeta-potential (n = 3). The zeta-potential of the powder was measured using the Nano-Zetasizer technique. The contact angle (wettability, surface free energy tests) were measured on nine samples using goniometer. The biofilm attachment onto the substrate was assessed on the samples of each material using microscope and image processing software. The data were compared using one-way ANOVA with Dunnett post-hoc tests at a level of significance P ≤ 0.05. Both STL materials showed similar physico-chemical properties to dentine. The materials and dentine had negative charge (Accura: -23.7 mv, Photopolymer: -18.8 mv, dentine: -9.11 mv). The wettability test showed that all test materials were hydrophilic with a contact angle of 47.5°, 39.8°, 36.1° for Accura, Photopolymer and dentine respectively, and a surface free energy of 46.6, 57.7, 59.6 mN/m for Accura, Photopolymer and dentine, respectively. The materials and dentine proved suitable for attachment and growth of E. faecalis biofilm with no statistical differences (P > 0.05). Stereolithography materials show similar physico-chemical properties and growth of E. faecalis biofilm to dentine. Therefore, they may be an alternative to tests requiring dentine.
© 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  Enterococcus faecalis; biofilm; dentine; physico-chemical properties; stereolithography materials

Mesh:

Substances:

Year:  2016        PMID: 27813213     DOI: 10.1002/jemt.22788

Source DB:  PubMed          Journal:  Microsc Res Tech        ISSN: 1059-910X            Impact factor:   2.769


  2 in total

1.  A cross-linking strategy with moderated pre-polymerization of resin for stereolithography.

Authors:  Rongping Ni; Bin Qian; Chang Liu; Xiaofeng Liu; Jianrong Qiu
Journal:  RSC Adv       Date:  2018-08-21       Impact factor: 4.036

2.  The impact of 3D-printed LAY-FOMM 40 and LAY-FOMM 60 on L929 cells and human oral fibroblasts.

Authors:  Gunpreet Oberoi; Sophie Nitsch; Klara Janjić; Hassan Shokoohi-Tabrizi; Andreas Moritz; Francesco Moscato; Ewald Unger; Hermann Agis
Journal:  Clin Oral Investig       Date:  2020-09-20       Impact factor: 3.573

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.