Literature DB >> 27812254

Evaluation of Magnetized-Erythrocyte Group Antigens to Detect ABO Antibodies.

O Nathalang1, K Intharanut1, P Sriwanitchrak1, M Setthakarn2, S Duan3, H Wang3, S Ding3, Y Li3.   

Abstract

Screening for IgM titers of anti-A and anti-B is recommended when providing ABO incompatible platelet transfusion. The life-time of reagent cells depends upon the preservative diluents. We aimed to evaluate the IgM titers of anti-A and anti-B testing with magnetized-erythrocyte group antigens (MEGA) and fresh RBCs and study the relationship of ABO antibody titers between both techniques. Altogether, 100 serum samples from group O donors at the National Blood Centre, Thai Red Cross Society, Bangkok, Thailand were included. EDTA blood from three different A and B blood group individuals was prepared as fresh reagent RBCs and MEGA. Each serum sample was tested simultaneously for IgM anti-A and anti-B titers using fresh RBCs and MEGA by standard tube technique. Antibody titers were compared between both techniques. Test for reproducibility and stability of MEGA were performed. The IgM anti-A and anti-B titers using fresh RBCs yielded higher agglutination scores than MEGA (P < 0.001). However, a good correlation was obtained in the agglutination titers (anti-A, r = 0.838 and anti-B, r = 0.877). The mean and standard deviation of anti-A and anti-B titers using MEGA from five sera in triplicate showed no significant difference (P > 0.05). Moreover, the titer test results using MEGA after dilution remained stable up to 8 h. The MEGA can be used as a replacement for fresh RBCs to perform ABO serum grouping. It is simple to use, avoids centrifugation and provides good results in terms of stability and reproducibility.

Entities:  

Keywords:  Anti-A; Anti-B; IgM titers; Magnetized-erythrocyte group antigens

Year:  2015        PMID: 27812254      PMCID: PMC5074953          DOI: 10.1007/s12288-015-0613-3

Source DB:  PubMed          Journal:  Indian J Hematol Blood Transfus        ISSN: 0971-4502            Impact factor:   0.900


  16 in total

1.  ABO-incompatible bone marrow transplantation: the transfusion of incompatible plasma may exacerbate regimen-related toxicity.

Authors:  R J Benjamin; J H Antin
Journal:  Transfusion       Date:  1999 Nov-Dec       Impact factor: 3.157

2.  Apheresis platelet transfusions: does ABO matter?

Authors:  Jay H Herman; Karen E King
Journal:  Transfusion       Date:  2004-06       Impact factor: 3.157

3.  Transfusion of apheresis platelets and ABO groups.

Authors: 
Journal:  Vox Sang       Date:  2005-04       Impact factor: 2.144

Review 4.  ABO and platelet transfusion therapy.

Authors:  L Cooling
Journal:  Immunohematology       Date:  2007

5.  Differences in ABO antibody levels among blood donors: a comparison between past and present Japanese, Laotian, and Thai populations.

Authors:  T Mazda; R Yabe; O NaThalang; T Thammavong; K Tadokoro
Journal:  Immunohematology       Date:  2007

6.  Evaluation of immunohematologic routine methods using the new erythrocyte-magnetized technology on the QWALYS 2 system.

Authors:  Helge Schoenfeld; Katia Bulling; Christian von Heymann; Bruno Neuner; Ulrich Kalus; Holger Kiesewetter; Axel Pruss
Journal:  Transfusion       Date:  2009-03-23       Impact factor: 3.157

7.  Intravascular hemolysis secondary to ABO incompatible platelet products. An underrecognized transfusion reaction.

Authors:  S McManigal; K L Sims
Journal:  Am J Clin Pathol       Date:  1999-02       Impact factor: 2.493

8.  The characteristics of ABO antibodies in group O Thai blood donors.

Authors:  Kamontip Khampanon; Thanaporn Chanprakop; Pramote Sriwanitchrak; Manida Setthakarn; Sineenart Oota; Oytip Nathalang
Journal:  J Clin Lab Anal       Date:  2012-07       Impact factor: 2.352

9.  Acute intravascular hemolysis secondaryto out-of-group platelet transfusion.

Authors:  L G Larsson; V J Welsh; D J Ladd
Journal:  Transfusion       Date:  2000-08       Impact factor: 3.157

10.  Automation in immunohematology.

Authors:  Meenu Bajpai; Ravneet Kaur; Ekta Gupta
Journal:  Asian J Transfus Sci       Date:  2012-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.