Literature DB >> 2780997

In vitro dissolution of gallstones with MTBE: correlation with characteristics at CT and MR imaging.

R L Baron1, S J Kuyper, S P Lee, C A Rohrmann, W P Shuman, J A Nelson.   

Abstract

The authors undertook a study to determine whether in vitro computed tomography (CT) or magnetic resonance (MR) imaging could enable the prediction of the outcome of gallstone dissolution with methyl tert-butyl ether (MTBE). In vitro CT and MR images were obtained of gallstones removed at surgery from 40 and 30 patients, respectively. The patterns of the gallstones seen on CT scans were categorized as dense, moderately dense, faint, isodense, rimmed, and laminated. Gallstones were categorized by maximal signal intensities seen on T1-weighted MR images. After imaging, gallstones underwent in vitro MTBE dissolution. CT appearances correlated well with dissolution rates. Greatest weight change was noted in gallstones with homogeneously faint and isodense patterns, and least weight change was seen in stones with a homogeneously dense pattern. Rimmed and laminated stones with foci of high attenuation dissolved significantly to 5% or less of the original weight, a finding indicating that such foci do not preclude dissolution. Dissolution rates correlated with attenuation values of homogeneous stones (r = .8) and of the rim portion of rimmed stones (r = .8). No correlation was found between T1-weighted signal intensities on MR images and MTBE dissolution rates.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2780997     DOI: 10.1148/radiology.173.1.2780997

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  4 in total

1.  In vivo analysis of gallstone composition by computed tomography.

Authors:  J G Bova; W H Schwesinger; W E Kurtin
Journal:  Gastrointest Radiol       Date:  1992

2.  Computed tomography in predicting gall stone solubility: a prospective trial.

Authors:  A Caroli; G Del Favero; F Di Mario; F Spigariol; P Scalon; T Meggiato; C Zambelli; R Naccarato
Journal:  Gut       Date:  1992-05       Impact factor: 23.059

3.  Transhepatic topical dissolution of gallbladder stones with MTBE and EDTA. Results, side effects, and correlation with CT imaging.

Authors:  P Janowitz; K A Schumacher; W Swobodnik; W Kratzer; J Tudyka; J G Wechsler
Journal:  Dig Dis Sci       Date:  1993-11       Impact factor: 3.199

4.  Direct dissolution of gallstones with methyl tert-butyl ether (MTBE) via endoscopic transpapillary catheterization in the gallbladder (ETCG).

Authors:  N Uchida; T Nakatsu; S Hirabayashi; A Minami; H Fukuma; T Ezaki; S A Morshed; C Fuke; K Ameno; I Ijiri
Journal:  J Gastroenterol       Date:  1994-08       Impact factor: 7.527

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.