BACKGROUND: Sentinel lymph node biopsy (SLNB) is well accepted to be a standard procedure in breast cancer surgery with clinically negative lymph nodes. Isosulfan blue is the first dye approved by the USA Food and Drug Administration for the localization of the lymphatic system. Few alternative tracers have been investigated. In this study, we aimed to compare the differences between 10 % fluorescein sodium and 1 % isosulfan blue in breast sentinel lymph node biopsy and to investigate the feasibility of using 10 % fluorescein sodium as a new dye for breast sentinel lymph node biopsy.Entities:
Keywords: Breast sentinel lymph node biopsy; Fluorescein sodium; Isosulfan blue
Mesh:
Substances:
Year: 2016 PMID: 27809854 PMCID: PMC5093998 DOI: 10.1186/s12957-016-1031-1
Source DB: PubMed Journal: World J Surg Oncol ISSN: 1477-7819 Impact factor: 2.754
Fig. 1LTS-RN9070 blue light source system and goggle with blue light filter
General aspects of animals in two groups
| Variable | FS group | IS group |
|
|---|---|---|---|
| Body weight (kg) | 2.54 ± 0.17 | 2.56 ± 0.15 | 0.57 |
| Distance from SNP to SLN (cm) | 11.39 ± 3.14 | 12.34 ± 1.72 | 0.23 |
| Distance from SNP to 2nd LN (cm) | 15.09 ± 2.86 | 15.22 ± 1.64 | 0.89 |
FS fluorescein sodium, IS isosulfan blue, SNP the second pair of nipples, SLN sentinel lymph node, 2 the second lymph node
*p < 0.05
Fig. 2Percutaneously observable FS signal in a lymphatic vessel. The second mammary glands are stained by FS (arrow head), and the afferent lymphatic vessel is stained by FS (arrow)
Fig. 3Lymphatic vessel and lymph node stained by FS
Comparative analysis of various parameters between two groups
| Variable | FS group | IS group |
|
|---|---|---|---|
| Detection rate of ALV | 100 % (30/30) | 80 % (24/30) | 0.024* |
| Number of the 2nd LN | 1.36 ± 0.62 | 1.13 ± 0.65 | 0.92 |
| Dyeing time of the SLN (s) | 142 ± 69 | 206 ± 219 | 0.28 |
| Dyeing time of the 2nd LN (s) | 502 ± 417 | 483 ± 305 | 0.91 |
| Fading time of the SLN (s) | 4327 ± 2359 | 3482 ± 1680 | 0.3445 |
| Fading time of the 2nd LN (s) | 3918 ± 2196 | 1332 ± 443 | 0.0077* |
| Detection rate of the SLN | 100 % (30/30) | 80 % (24/30) | 0.024* |
FS fluorescein sodium, IS isosulfan blue, ALV afferent lymphatic vessels, SLN sentinel lymph node, 2 the second lymph node
*p < 0.05