Clemens von Birgelen1, Marlies M Kok2, Liefke C van der Heijden2, Peter W Danse3, Carl E Schotborgh4, Martijn Scholte5, R Melvyn Tjon Joe Gin3, Samer Somi4, K G van Houwelingen2, M G Stoel2, Frits H A F de Man2, J Hans W Louwerenburg2, Marc Hartmann2, Paolo Zocca2, Gerard C M Linssen6, Job van der Palen7, Carine J M Doggen8, Marije M Löwik2. 1. Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, Netherlands; Department of Health Technology and Services Research, MIRA-Institute of Technical Medicine and Biomedical Technology, University of Twente, Enschede, Netherlands. Electronic address: c.vonbirgelen@mst.nl. 2. Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, Netherlands. 3. Department of Cardiology, Rijnstate Hospital, Arnhem, Netherlands. 4. Department of Cardiology, Haga Hospital, The Hague, Netherlands. 5. Department of Cardiology, Albert Schweitzer Hospital, Dordrecht, Netherlands. 6. Department of Cardiology, Hospital Group Twente, Almelo and Hengelo, Netherlands. 7. Department of Epidemiology, Medisch Spectrum Twente, Enschede, Netherlands; Department of Research Methodology, Measurement and Data Analysis, University of Twente, Enschede, Netherlands. 8. Department of Health Technology and Services Research, MIRA-Institute of Technical Medicine and Biomedical Technology, University of Twente, Enschede, Netherlands.
Abstract
BACKGROUND: In patients with coronary artery disease, treated with durable polymer-coated drug-eluting stents, the life-long presence of the polymer might delay arterial healing. Novel very thin strut biodegradable polymer stents, which leave only a bare metal stent after polymer resorption, might improve long-term outcome. We investigated in allcomers the safety and efficacy of three stents eluting either everolimus, sirolimus, or zotarolimus, often clinically used but never compared, of which the biodegradable polymer everolimus-eluting stent was never before assessed in allcomers. METHODS: The large-scale, investigator-initiated, multicentre, assessor and patient blinded, three-arm, randomised, BIO-RESORT non-inferiority trial was done at four clinical sites in the Netherlands. All-comer patients were aged 18 years or older, capable of providing informed consent, and required a percutaneous coronary intervention with drug-eluting stent implantation according to clinical guidelines or the operators' judgment. Exclusion criteria were: participation in another randomised drug or device study before reaching the primary endpoint of that study; planned surgery necessitating interruption of dual antiplatelet therapy within the first 6 months; known intolerance to components of the investigational product or medication required; uncertainty about the adherence to follow-up procedures or an assumed life expectancy of less than 1 year; or known pregnancy. Web-based computer-generated allocation sequences randomly assigned patients (1:1:1) to treatment with very thin strut biodegradable polymer everolimus-eluting or sirolimus-eluting stents (which differ substantially in type, amount, distribution, and resorption speed of their respective coating), or thin strut durable polymer zotarolimus-eluting stents. The primary endpoint was a composite of safety (cardiac death or target vessel-related myocardial infarction) and efficacy (target vessel revascularisation) at 12 months of follow up with a very thin strut biodegradable polymer of either everolimus-eluting or sirolimus-eluting stents, compared with durable polymer zotarolimus-eluting stents, analysed by intention to treat (non-inferiority margin 3·5%). This trial was registered with ClinicalTrials.gov, number NCT01674803. FINDINGS:From Dec 21, 2012, to Aug 24, 2015, 3514 patients were enrolled and analysed, of whom 2449 (70%) had acute coronary syndromes, which included 1073 (31%) ST-elevation myocardial infarctions. 12 month follow-up of 3490 (99%) patients (three lost to follow-up; 21 withdrawals) was available. The primary endpoint was met by 55 (5%) of 1172 patients assigned to everolimus-eluting stents, 55 (5%) of 1169 assigned to sirolimus-eluting stents and 63 (5%) of 1173 assigned tozotarolimus-eluting stents. Non-inferiority of the everolimus-eluting stents and sirolimus-eluting stents compared with zotarolimus-eluting stents was confirmed (both -0·7% absolute risk difference, 95% CI -2·4 to 1·1; upper limit of one sided 95% CI 0·8%, pnon-inferiority<0·0001). Definite stent thrombosis (defined by the Academic Research Consortium) occurred in four (0·3%) of 1172 patients who were allocated to everolimus-eluting stents, four (0·3%) of 1169 patients who were allocated to sirolimus-eluting stents, and three (0·3%) of 1173 patients who were allocated tozotarolimus-eluting stents (log-rank p=0·70 for both comparisons with zotarolimus-eluting stents). INTERPRETATION: At 12 month follow-up, both very thin strut drug-eluting stents with dissimilar biodegradable polymer coatings (eluting either everolimus or sirolimus) were non-inferior to the durable polymer stent (eluting zotarolimus) in treating allcomers with a high proportion of patients with acute coronary syndromes. The absence of a loss of 1 year safety and efficacy with the use of these two biodegradable polymer-coated stents is a prerequisite before assessing their potential longer-term benefits. FUNDING: Biotronik, Boston Scientific, and Medtronic. Copyright Â
RCT Entities:
BACKGROUND: In patients with coronary artery disease, treated with durable polymer-coated drug-eluting stents, the life-long presence of the polymer might delay arterial healing. Novel very thin strut biodegradable polymer stents, which leave only a bare metal stent after polymer resorption, might improve long-term outcome. We investigated in allcomers the safety and efficacy of three stents eluting either everolimus, sirolimus, or zotarolimus, often clinically used but never compared, of which the biodegradable polymer everolimus-eluting stent was never before assessed in allcomers. METHODS: The large-scale, investigator-initiated, multicentre, assessor and patient blinded, three-arm, randomised, BIO-RESORT non-inferiority trial was done at four clinical sites in the Netherlands. All-comer patients were aged 18 years or older, capable of providing informed consent, and required a percutaneous coronary intervention with drug-eluting stent implantation according to clinical guidelines or the operators' judgment. Exclusion criteria were: participation in another randomised drug or device study before reaching the primary endpoint of that study; planned surgery necessitating interruption of dual antiplatelet therapy within the first 6 months; known intolerance to components of the investigational product or medication required; uncertainty about the adherence to follow-up procedures or an assumed life expectancy of less than 1 year; or known pregnancy. Web-based computer-generated allocation sequences randomly assigned patients (1:1:1) to treatment with very thin strut biodegradable polymer everolimus-eluting or sirolimus-eluting stents (which differ substantially in type, amount, distribution, and resorption speed of their respective coating), or thin strut durable polymerzotarolimus-eluting stents. The primary endpoint was a composite of safety (cardiac death or target vessel-related myocardial infarction) and efficacy (target vessel revascularisation) at 12 months of follow up with a very thin strut biodegradable polymer of either everolimus-eluting or sirolimus-eluting stents, compared with durable polymerzotarolimus-eluting stents, analysed by intention to treat (non-inferiority margin 3·5%). This trial was registered with ClinicalTrials.gov, number NCT01674803. FINDINGS: From Dec 21, 2012, to Aug 24, 2015, 3514 patients were enrolled and analysed, of whom 2449 (70%) had acute coronary syndromes, which included 1073 (31%) ST-elevation myocardial infarctions. 12 month follow-up of 3490 (99%) patients (three lost to follow-up; 21 withdrawals) was available. The primary endpoint was met by 55 (5%) of 1172 patients assigned to everolimus-eluting stents, 55 (5%) of 1169 assigned to sirolimus-eluting stents and 63 (5%) of 1173 assigned to zotarolimus-eluting stents. Non-inferiority of the everolimus-eluting stents and sirolimus-eluting stents compared with zotarolimus-eluting stents was confirmed (both -0·7% absolute risk difference, 95% CI -2·4 to 1·1; upper limit of one sided 95% CI 0·8%, pnon-inferiority<0·0001). Definite stent thrombosis (defined by the Academic Research Consortium) occurred in four (0·3%) of 1172 patients who were allocated to everolimus-eluting stents, four (0·3%) of 1169 patients who were allocated to sirolimus-eluting stents, and three (0·3%) of 1173 patients who were allocated to zotarolimus-eluting stents (log-rank p=0·70 for both comparisons with zotarolimus-eluting stents). INTERPRETATION: At 12 month follow-up, both very thin strut drug-eluting stents with dissimilar biodegradable polymer coatings (eluting either everolimus or sirolimus) were non-inferior to the durable polymer stent (eluting zotarolimus) in treating allcomers with a high proportion of patients with acute coronary syndromes. The absence of a loss of 1 year safety and efficacy with the use of these two biodegradable polymer-coated stents is a prerequisite before assessing their potential longer-term benefits. FUNDING: Biotronik, Boston Scientific, and Medtronic. Copyright Â
Authors: Rosaly A Buiten; Eline H Ploumen; Paolo Zocca; Carine J M Doggen; Liefke C van der Heijden; Marlies M Kok; Peter W Danse; Carl E Schotborgh; Martijn Scholte; Frits H A F de Man; Gerard C M Linssen; Clemens von Birgelen Journal: JAMA Cardiol Date: 2019-07-01 Impact factor: 14.676
Authors: Jacopo Burrello; Guglielmo Gallone; Alessio Burrello; Daniele Jahier Pagliari; Eline H Ploumen; Mario Iannaccone; Leonardo De Luca; Paolo Zocca; Giuseppe Patti; Enrico Cerrato; Wojciech Wojakowski; Giuseppe Venuti; Ovidio De Filippo; Alessio Mattesini; Nicola Ryan; Gérard Helft; Saverio Muscoli; Jing Kan; Imad Sheiban; Radoslaw Parma; Daniela Trabattoni; Massimo Giammaria; Alessandra Truffa; Francesco Piroli; Yoichi Imori; Bernardo Cortese; Pierluigi Omedè; Federico Conrotto; Shao-Liang Chen; Javier Escaned; Rosaly A Buiten; Clemens Von Birgelen; Paolo Mulatero; Gaetano Maria De Ferrari; Silvia Monticone; Fabrizio D'Ascenzo Journal: J Pers Med Date: 2022-06-17
Authors: Mahesh V Madhavan; James P Howard; Azim Naqvi; Ori Ben-Yehuda; Bjorn Redfors; Megha Prasad; Bahira Shahim; Martin B Leon; Sripal Bangalore; Gregg W Stone; Yousif Ahmad Journal: Eur Heart J Date: 2021-07-15 Impact factor: 29.983
Authors: Liefke C van der Heijden; Marlies M Kok; Paolo Zocca; Hanim Sen; Marije M Löwik; Silvia Mariani; Frits H A F de Man; Marc Hartmann; Martin G Stoel; K Gert van Houwelingen; J Hans W Louwerenburg; Gerard C M Linssen; Carine J M Doggen; Jan G Grandjean; Clemens von Birgelen Journal: J Am Heart Assoc Date: 2018-01-30 Impact factor: 5.501
Authors: Elvin Kedhi; Enrico Fabris; Martin van der Ent; Pawel Buszman; Clemens von Birgelen; Vincent Roolvink; Alexander Zurakowski; Carl E Schotborgh; Jan C A Hoorntje; Christian Hasbø Eek; Stéphane Cook; Marco Togni; Martijn Meuwissen; Niels van Royen; Ria van Vliet; Hans Wedel; Ronak Delewi; Felix Zijlstra Journal: BMJ Date: 2018-10-02
Authors: Paolo Zocca; Marlies M Kok; Liefke C van der Heijden; Peter W Danse; Carl E Schotborgh; Martijn Scholte; Marc Hartmann; Gerard C M Linssen; Carine J M Doggen; Clemens von Birgelen Journal: Cardiovasc Drugs Ther Date: 2018-12 Impact factor: 3.727