Influence of Thermal Cycling on Flexural Properties and Simulated Wear of Computer-aided Design/Computer-aided Manufacturing Resin Composites.

A Tsujimoto, W W Barkmeier, T Takamizawa, M A Latta, M Miyazaki.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the influence of thermal cycling on the flexural properties and simulated wear of computer-aided design/computer-aided manufacturing (CAD/CAM) resin composites.
METHODS: The six CAD/CAM resin composites used in this study were 1) Lava Ultimate CAD/CAM Restorative (LU); 2) Paradigm MZ100 (PM); 3) CERASMART (CS); 4) Shofu Block HC (SB); 5) KATANA AVENCIA Block (KA); and 6) VITA ENAMIC (VE). Specimens were divided randomly into two groups, one of which was stored in distilled water for 24 hours, and the other of which was subjected to 10,000 thermal cycles. For each material, 15 specimens from each group were used to determine the flexural strength and modulus according to ISO 6872, and 20 specimens from each group were used to examine wear using a localized wear simulation model. The test materials were subjected to a wear challenge of 400,000 cycles in a Leinfelder-Suzuki device (Alabama machine). The materials were placed in custom-cylinder stainless steel fixtures, and simulated localized wear was generated using a stainless steel ball bearing (r=2.387 mm) antagonist in a water slurry of polymethyl methacrylate beads. Simulated wear was determined using a noncontact profilometer (Proscan 2100) with Proscan and AnSur 3D software.
RESULTS: The two-way analysis of variance of flexural properties and simulated wear of CAD/CAM resin composites revealed that material type and thermal cycling had a significant influence (p<0.05), but there was no significant interaction (p>0.05) between the two factors. The flexural properties and maximum depth of wear facets of CAD/CAM resin composite were different (p<0.05) depending on the material, and their values were influenced (p>0.05) by thermal cycling, except in the case of VE. The volume losses in wear facets on LU, PM, and SB after 10,000 thermal cycles were significantly higher (p<0.05) than those after 24 hours of water storage, unlike CS, KA, and VE.
CONCLUSION: The results of this study indicate that the flexural properties and simulated wear of CAD/CAM resin composites are different depending on the material. In addition, the flexural properties and simulated wear of CAD/CAM resin composites are influenced by thermal cycling.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27802120     DOI: 10.2341/16-046-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  8 in total

1.  Polishing effects and wear performance of chairside CAD/CAM materials.

Authors:  Mike Matzinger; Sebastian Hahnel; Verena Preis; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2018-05-16       Impact factor: 3.573

2.  Sliding contact wear and subsurface damage of CAD/CAM materials against zirconia.

Authors:  M Wendler; M R Kaizer; R Belli; U Lohbauer; Y Zhang
Journal:  Dent Mater       Date:  2020-01-30       Impact factor: 5.304

Review 3.  Fatigue bond strength of dental adhesive systems: Historical background of test methodology, clinical considerations and future perspectives.

Authors:  Akimasa Tsujimoto; Wayne W Barkmeier; Erica C Teixeira; Toshiki Takamizawa; Masashi Miyazaki; Mark A Latta
Journal:  Jpn Dent Sci Rev       Date:  2022-06-25

4.  Color stability of fully- and pre-crystalized chair-side CAD-CAM lithium disilicate restorations after required and additional sintering processes.

Authors:  Carlos Alberto Jurado; Tamer El-Gendy; Jared Hyer; Akimasa Tsujimoto
Journal:  J Adv Prosthodont       Date:  2022-02-25       Impact factor: 1.904

Review 5.  Wear of resin composites: Current insights into underlying mechanisms, evaluation methods and influential factors.

Authors:  Akimasa Tsujimoto; Wayne W Barkmeier; Nicholas G Fischer; Kie Nojiri; Yuko Nagura; Toshiki Takamizawa; Mark A Latta; Masashi Miazaki
Journal:  Jpn Dent Sci Rev       Date:  2017-12-11

6.  A Comparative Study on the Mechanical Properties of a Polymer-Infiltrated Ceramic-Network Material Used for the Fabrication of Hybrid Abutment.

Authors:  Salim Ongun; Sevcan Kurtulmus-Yilmaz; Gökçe Meriç; Mutahhar Ulusoy
Journal:  Materials (Basel)       Date:  2018-09-11       Impact factor: 3.623

7.  Wear resistance of indirect composite resins used for provisional restorations supported by implants.

Authors:  Akimasa Tsujimoto; Carlos Jurado; Jose Villalobos-Tinoco; Wayne Barkmeier; Nicholas Fischer; Toshiki Takamizawa; Mark Latta; Masashi Miyazaki
Journal:  J Adv Prosthodont       Date:  2019-08-27       Impact factor: 1.904

8.  Thermoanalytical Investigations on the Influence of Storage Time in Water of Resin-Based CAD/CAM Materials.

Authors:  Martin Rosentritt; Sibylle Schneider-Feyrer; Thomas Strasser; Andreas Koenig; Leonie Schmohl; Alois Schmid
Journal:  Biomedicines       Date:  2021-11-26