Literature DB >> 27798318

Comparing Usual Care With a Warfarin Initiation Protocol After Mechanical Heart Valve Replacement.

Gregory Roberts1,2, Rasha Razooqi3, Stephen Quinn2.   

Abstract

BACKGROUND: The immediate postoperative warfarin sensitivity for patients receiving heart valve prostheses is increased. Established warfarin initiation protocols may lack clinical applicability, resulting in dosing based on clinical judgment.
OBJECTIVE: To compare current practice for warfarin initiation with a known warfarin initiation protocol, with doses proportionally reduced to account for the increased postoperative sensitivity.
METHODS: We compared the Mechanical Heart Valve Warfarin Initiation Protocol (Protocol group) with current practice (clinical judgment-Empirical group) for patients receiving mechanical heart valves in an observational before-and-after format. End points were the time to achieve a stable therapeutic international normalized ratio (INR), doses held in the first 6 days, and overanticoagulation in the first 6 days.
RESULTS: The Protocol group (n = 37) achieved a stable INR more rapidly than the Empirical group (n = 77; median times 5.1 and 8.7 days, respectively; P = 0.002). Multivariable analysis indicated that the Protocol group (hazard ratio [HR] = 2.22; P = 0.005) and men (HR = 1.76; P = 0.043) more rapidly achieved a stable therapeutic INR. Age, serum albumin, amiodarone, presence of severe heart failure, and surgery type had no impact. Protocol patients had fewer doses held (1.1% vs 10.1%, P < 0.001) and no difference in overanticoagulation (2.7% vs 9.1%, P = 0.27).
CONCLUSION: The Mechanical Heart Valve Warfarin Initiation Protocol provided a reliable approach to initiating warfarin in patients receiving mechanical aortic or mitral valves.

Entities:  

Keywords:  anticoagulation; cardiovascular drugs; clinical pharmacy; dosing; surgery; warfarin

Mesh:

Substances:

Year:  2016        PMID: 27798318     DOI: 10.1177/1060028016676830

Source DB:  PubMed          Journal:  Ann Pharmacother        ISSN: 1060-0280            Impact factor:   3.154


  5 in total

1.  Predictors of bleeding event among elderly patients with mechanical valve replacement using random forest model: A retrospective study.

Authors:  Jisu Kim; InSil Jang
Journal:  Medicine (Baltimore)       Date:  2021-05-14       Impact factor: 1.889

2.  A Study of the Nursing Intervention Based on Self-Efficacy Theory for Patients After Mechanical Heart Valve Replacement: A Randomized Controlled Trial.

Authors:  Fei Jiang; Yanjuan Lin; Sailan Li; Yanchun Peng; Xizhen Huang; Liangwan Chen
Journal:  Int J Gen Med       Date:  2022-08-09

3.  Identification of clinical factors predicting warfarin sensitivity after cardiac surgery.

Authors:  Karen Tyson; Nevil Hutchinson; Sian Williams; Greg Scutt
Journal:  Ther Adv Drug Saf       Date:  2018-06-05

4.  Factors Affecting Medication Adherence in Patients with Mechanical Heart Valves Taking Warfarin: The Role of Knowledge on Warfarin, Medication Belief, Depression, and Self-Efficacy.

Authors:  Soohyun Park; Insil Jang
Journal:  Int J Environ Res Public Health       Date:  2021-05-14       Impact factor: 3.390

5.  Comparison of Warfarin Initiation at 3 mg Versus 5 mg for Anticoagulation of Patients with Mechanical Mitral Valve Replacement Surgery: A Prospective Randomized Trial.

Authors:  Sarah Sabry; Lamia Mohamed El Wakeel; Ayman Saleh; Marwa Adel Ahmed
Journal:  Clin Drug Investig       Date:  2022-03-10       Impact factor: 2.859

  5 in total