Literature DB >> 27798076

EtG and EtS in Autopsy Blood Samples With and Without Putrefaction Using UPLC-MS-MS.

Solfrid Hegstad1, Lena Kristoffersen2, Veronica H Liane2, Olav Spigset1,3.   

Abstract

Analytical challenges related to postmortem specimens are well known. The degree of putrefaction of the corpse will influence the quality of the blood samples, and both the efficiency of sample preparation and the subsequent chromatographic performance can be affected. An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method was developed and validated for the determination of ethyl glucuronide (EtG) and ethyl sulfate (EtS) in postmortem whole blood. Sample preparation prior to UPLC-MS-MS analysis consisted of protein precipitation and filtration through a phospholipid removal plate. Chromatography was achieved using an HSS T3 column and gradient elution with formic acid in water in combination with methanol. The injection volume was 0.5 µL. Negative electrospray ionization was performed in the multiple reaction monitoring mode. Two transitions were monitored for the analytes and one for the internal standards. The between-assay relative standard deviations were in the range of 1.7-7.0% and the limits of quantification were 0.025 and 0.009 mg/L for EtG and EtS, respectively. Recovery was 51-55% and matrix effects ranged from 98% to 106% (corrected with internal standard). Blood samples from nine autopsy cases with various extents of putrefaction were analyzed. The sample preparation efficiently removed the phospholipids from the blood specimens. The samples were clean and the analytical quality of the chromatographic performance was satisfactory for both analytes irrespective of the degree of putrefaction.
© The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 27798076     DOI: 10.1093/jat/bkw123

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  1 in total

1.  Development of a Column-Switching HPLC-MS/MS Method and Clinical Application for Determination of Ethyl Glucuronide in Hair in Conjunction with AUDIT for Detecting High-Risk Alcohol Consumption.

Authors:  Yeon Gyeong Kim; Jihye Hwang; Hwakyung Choi; Sooyeun Lee
Journal:  Pharmaceutics       Date:  2018-07-04       Impact factor: 6.321

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.