Literature DB >> 27796066

Decline in ventricular function as a result of general anesthesia in pediatric heart transplant recipients.

Justin J Elhoff1, Shahryar M Chowdhury1, Carolyn L Taylor1, Marc Hassid2, Andrew J Savage1, Andrew M Atz1, Ryan J Butts1.   

Abstract

Echocardiography is frequently performed under anesthesia during procedures such as cardiac catheterization with EMB in pediatric HTx recipients. Anesthetic agents may depress ventricular function, resulting in concern for rejection. The aim of this study was to compare ventricular function as measured by echocardiography before and during GA in 17 pediatric HTx recipients. Nearly all markers of ventricular systolic function were significantly decreased under GA, including EF (-4.2% ±1.2, P < .01) and RV FAC (-0.05 ± 0.02, P = .04). Subjects in the first post-transplant year (n = 9) trended toward a more significant decrease in EF vs those beyond the first post-transplant year (n = 8; -6.0% ±1.2 vs -2.1 ± 2.0, P = .1). This information quantifies a decline in biventricular function that should be expected in pediatric HTx recipients while under GA and can assist the transplant clinician in avoiding unnecessary treatment of transient GA-induced ventricular dysfunction.
© 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  anesthesia; cardiac function; echocardiography; graft function; pediatric heart transplant

Mesh:

Substances:

Year:  2016        PMID: 27796066      PMCID: PMC5558209          DOI: 10.1111/petr.12825

Source DB:  PubMed          Journal:  Pediatr Transplant        ISSN: 1397-3142


  27 in total

1.  Ultrasonic strain/strain rate imaging--a new clinical tool to evaluate the transplanted heart.

Authors:  Elif Eroglu; Lieven Herbots; Johan Van Cleemput; Walter Droogne; Piet Claus; Jan D'hooge; Bart Bijnens; Johan Vanhaecke; George R Sutherland
Journal:  Eur J Echocardiogr       Date:  2005-06

2.  The potential clinical role of ultrasonic strain and strain rate imaging in diagnosing acute rejection after heart transplantation.

Authors:  Anna Marciniak; Elif Eroglu; Maciej Marciniak; Cristina Sirbu; Lieven Herbots; Walter Droogne; Piet Claus; Jan D'hooge; Bart Bijnens; Johan Vanhaecke; George R Sutherland
Journal:  Eur J Echocardiogr       Date:  2006-05-23

3.  Tissue Doppler-derived diastolic myocardial velocities are abnormal in pediatric cardiac transplant recipients in the absence of endomyocardial rejection.

Authors:  Sebastian Strigl; Rose Hardy; Julie S Glickstein; Daphne T Hsu; Linda J Addonizio; Jacqueline M Lamour; Ashwin Prakash
Journal:  Pediatr Cardiol       Date:  2008-01-05       Impact factor: 1.655

4.  Noninvasive single-beat determination of left ventricular end-systolic elastance in humans.

Authors:  C H Chen; B Fetics; E Nevo; C E Rochitte; K R Chiou; P A Ding; M Kawaguchi; D A Kass
Journal:  J Am Coll Cardiol       Date:  2001-12       Impact factor: 24.094

5.  Myocardial performance index with sevoflurane-pancuronium versus fentanyl-midazolam-pancuronium in infants with a functional single ventricle.

Authors:  Catherine M Ikemba; Jason T Su; Stephen A Stayer; Wanda C Miller-Hance; Benjamin W Eidem; Louis I Bezold; Stuart R Hall; Luke M Havemann; Dean B Andropoulos
Journal:  Anesthesiology       Date:  2004-12       Impact factor: 7.892

6.  Cardiac allograft function during the first year after transplantation in rejection-free children and young adults.

Authors:  Fatima I Lunze; Steven D Colan; Kimberlee Gauvreau; Ming Hui Chen; Antonio R Perez-Atayde; Elizabeth D Blume; Tajinder P Singh
Journal:  Circ Cardiovasc Imaging       Date:  2012-09-21       Impact factor: 7.792

7.  Echocardiographic indexes of allograft rejection in pediatric cardiac transplant recipients.

Authors:  M A Frommelt; A R Snider; D C Crowley; J N Meliones; K P Heidelberger
Journal:  J Am Soc Echocardiogr       Date:  1992 Jan-Feb       Impact factor: 5.251

8.  Validation of Noninvasive Measures of Left Ventricular Mechanics in Children: A Simultaneous Echocardiographic and Conductance Catheterization Study.

Authors:  Shahryar M Chowdhury; Ryan J Butts; Carolyn L Taylor; Varsha M Bandisode; Karen S Chessa; Anthony M Hlavacek; Girish S Shirali; G Hamilton Baker
Journal:  J Am Soc Echocardiogr       Date:  2016-03-26       Impact factor: 5.251

9.  Relative vs. absolute values: using patient and population norms for echocardiography in pediatric cardiac transplant recipients.

Authors:  Katherine K Raczek; Frederick Dorey; Pierre C Wong; Jacqueline R Szmuszkovicz; Jondavid Menteer
Journal:  Pediatr Transplant       Date:  2009-04-07

10.  Serial echocardiographic evaluation of cardiac graft rejection after infant heart transplantation.

Authors:  M M Boucek; C M Mathis; M S Kanakriyeh; D D Hodgkin; R J Boucek; L L Bailey
Journal:  J Heart Lung Transplant       Date:  1993 Sep-Oct       Impact factor: 10.247

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.