| Literature DB >> 27795928 |
Pierre Dubrulle1, Franck Fajnkuchen2, Lise Qu1, Audrey Giocanti-Aurégan1.
Abstract
We reported a new complication after dexamethasone implant injection. The patient was treated by dexamethasone implant injection for diabetic macular edema. After injection, we report an implant stucked in Berger's space behind the crystalline lens capsule in the visual axis. This situation resolved after cataract surgery and the implant moved to a less inconvenient localization.Entities:
Keywords: Cataract; Diabetic macular edema; Ozurdex implant; Treatment complications
Year: 2016 PMID: 27795928 PMCID: PMC5063824 DOI: 10.1186/s40064-016-3490-9
Source DB: PubMed Journal: Springerplus ISSN: 2193-1801
Fig. 1Slit lamp photography of a 63 year old diabetic woman with dexamethasone implant confined in Berger’s space, between the anterior hyaloid and posterior lens capsule
Fig. 2Slit lamp photography, after cataract surgery. Dexamethasone implant is not visible in Berger’s space