Differences of standard values of Supersonic shear imaging and ARFI technique - in vivo study of testicular tissue.

M Trottmann1, J Rübenthaler2, J Marcon1, C G Stief1, M F Reiser2, D A Clevert2.   

Abstract

PURPOSE: To investigate the difference of standard values of Supersonic shear imaging (SSI) and Acoustic Radiation Force Impulse (ARFI) technique in the evaluation of testicular tissue stiffness in vivo.
MATERIALS AND METHODS: 58 healthy male testes were examined using B-mode sonography and ARFI and SSI. B-mode sonography was performed in order to scan the testis for pathologies followed by performance of real-time elastography in three predefined areas (upper pole, central portion and lower pole) using the SuperSonic® Aixplorer ultrasound device (SuperSonic Imagine, Aix-en-Provence, France). Afterwards a second assessment of the same testicular regions by elastography followed using the ARFI technique of the Siemens Acuson 2000™ ultrasound device (Siemens Health Care, Germany). Values of shear wave velocity were described in m/s. Parameters of elastography techniques were compared using paired sample t-test.
RESULTS: The values of SSI were all significantly higher in all measured areas compared to ARFI (p < 0.001 to p = 0.015). Quantitatively there was a higher mean SSI wave velocity value of 1,1 compared to 0.8 m/s measured by ARFI.
CONCLUSION: SSI values are significantly higher than ARFI values when measuring the stiffness of testicular tissue and should only be compared with caution.

Keywords:  Testis; shear-wave elastography; ultrasonography

Mesh:

Year:  2016        PMID: 27792000     DOI: 10.3233/CH-168039

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  4 in total

Review 1.  [Sonoelastography in daily clinical routine].

Authors:  J Rübenthaler; K Müller-Peltzer; M Reiser; D Rjosk-Dendorfer; D-A Clevert
Journal:  Radiologe       Date:  2017-05       Impact factor: 0.635

2.  Elastography of focal testicular lesions: current concepts and utility.

Authors:  Cheng Fang; Dean Y Huang; Paul S Sidhu
Journal:  Ultrasonography       Date:  2019-01-30

3.  Achilles Tendon Softness and Thickness in Patients With Hypercholesterolemia.

Authors:  Arul Murugan; Kirubhakaran Kanakaraju; Sidesh R M; Vandana Sanjoy Mishra
Journal:  Cureus       Date:  2022-08-24

4.  Elasticity standard values of the Achilles tendon assessed with acoustic radiation force impulse elastography on healthy volunteers: a cross section study.

Authors:  Jonas Wakker; Wolfgang Kratzer; Tilmann Graeter; Julian Schmidberger
Journal:  BMC Musculoskelet Disord       Date:  2018-05-09       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.