Literature DB >> 27790793

EVALUATION OF THE COMPUTED TOMOGRAPHIC "SENTINEL CLOT SIGN" TO IDENTIFY BLEEDING ABDOMINAL ORGANS IN DOGS WITH HEMOABDOMEN.

Swan Specchi1, Edoardo Auriemma1, Simona Morabito1, Filippo Ferri2, Eric Zini2, Valentina Piola3, Pascaline Pey4,5, Federica Rossi4,3.   

Abstract

The CT "sentinel clot sign" has been defined as the highest attenuation hematoma adjacent to a bleeding organ in humans with hemoabdomen. The aims of this retrospective descriptive multicenter study were to describe CT findings in a sample of dogs with surgically or necropsy confirmed intra-abdominal bleeding and determine prevalence of the "sentinel clot sign" adjacent to the location of bleeding. Medical records between 2012 and 2014 were searched for dogs with hemoabdomen and in which the origin of the bleeding was confirmed either with surgery or necropsy. Retrieved CT images were reviewed for the presence and localization of the "sentinel clot sign," HU measurements of the "sentinel clot sign" and hemoabdomen, and presence of extravasation of contrast media within the abdominal cavity. Nineteen dogs were included. Three dogs were excluded due to the low amount of blood that did not allow the identification of a "sentinel clot sign." A "sentinel clot sign" was detected in the proximity of the confirmed bleeding organ in 14/16 (88%) of the patients. The mean HU of the "sentinel clot sign" was 56 (range: 43-70) while that of the hemoabdomen was 34 (range: 20-45). Active hemorrhage was identified as extravasation of contrast medium within the peritoneal cavity from the bleeding organ in three dogs. In conclusion, the CT "sentinel clot sign" may be helpful for identifying the source of bleeding in dogs with hemoabdomen.
© 2016 American College of Veterinary Radiology.

Entities:  

Keywords:  CT; canine; sentinel clot sign; small animals; spleen

Mesh:

Year:  2016        PMID: 27790793     DOI: 10.1111/vru.12439

Source DB:  PubMed          Journal:  Vet Radiol Ultrasound        ISSN: 1058-8183            Impact factor:   1.363


  2 in total

1.  Diagnostic accuracy of postmortem computed tomography for bleeding source determination in cases with hemoperitoneum.

Authors:  Vasiliki Chatzaraki; Michael J Thali; Garyfalia Ampanozi
Journal:  Int J Legal Med       Date:  2021-01-07       Impact factor: 2.686

2.  Non-coagulopathic hemothorax in a dog: A case report.

Authors:  Danielle LaVine; Bobbi Conner; Gregory B Daniel; Mark Freeman
Journal:  Clin Case Rep       Date:  2022-09-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.