Literature DB >> 2778897

Optimal graft diameter: effect of wall shear stress on vascular healing.

R L Binns1, D N Ku, M T Stewart, J P Ansley, K A Coyle.   

Abstract

Arterial walls tend to adapt to maintain a specific wall shear stress. The formation of neointimal hyperplasia and endothelial cell healing of polytetrafluoroethylene grafts may also be governed by wall shear stress, which suggests that an optimal graft diameter may exist. To test this, 40 polytetrafluoroethylene grafts with internal diameters of 3, 6, and 8 mm were inserted end to end in the femoral and carotid arteries of 10 mongrel dogs. Total flow and diameter were measured, and grafts were stained with Evans blue dye, fixed by pressure perfusion, and analyzed by computer for anastomotic neointimal thickening, graft pseudointimal thickening, and degree of endothelial coverage. Mean calculated shear stress was 41 dyne/cm2 for the 3 mm grafts, 7 dyne/cm2 for the 6 mm grafts, and 3 dyne/cm2 for the 8 mm grafts. Fifteen weeks later the patency rate was 0 of 10 for the 3 mm grafts, 16 of 20 for the 6 mm grafts, and 7 of 10 for the 8 mm grafts. The mean graft shear stress was calculated to be 10 dyne/cm2 for the 6 mm grafts and 4 dyne/cm2 for the 8 mm grafts. Pseudointima lining the graft was composed of disorganized protein and cell remnants. The rough surface contained no overlying endothelium. Anastomotic neointima contained a layer of well-organized smooth muscle cells covered by a single layer of polygonal-shaped endothelial cells. A transition zone of thrombus, which is sandwiched by a wedge of smooth muscle cells near the graft surface and covered by endothelial cells, is described. Mean thickness of pseudointima of the patent 8 mm grafts was 150 microns thicker than that of the 6 mm grafts. Anastomotic neointimal thickness was 110 microns thicker in the 8 mm grafts compared with the 6 mm grafts. Among the 6 mm grafts, the carotid grafts had an average initial shear stress of 10 dyne/cm2, whereas the femoral grafts averaged a lower 5 dyne/cm2 and yielded pseudointima and neointima that were 40 microns thicker. The percent graft surface area covered with neointima did not differ among the grafts of differing diameter either proximally or distally. Lower shear stresses produced greater amounts of pseudointimal thickening within polytetrafluoroethylene grafts and neointimal thickening at their anastomoses. Conversely, the high shear stress from small-diameter grafts was associated with poor graft patency. These results suggest that an optimal graft diameter may help to prevent neointimal hyperplasia and graft thrombosis.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2778897

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  9 in total

1.  Numerical Simulation of Physiological Blood Flow in 2-way Coronary Artery Bypass Grafts.

Authors:  Aike Qiao; Youjun Liu; Siyang Li; Hu Zhao
Journal:  J Biol Phys       Date:  2005-05       Impact factor: 1.365

2.  Stress Analysis-Driven Design of Bilayered Scaffolds for Tissue-Engineered Vascular Grafts.

Authors:  Jason M Szafron; Christopher K Breuer; Yadong Wang; Jay D Humphrey
Journal:  J Biomech Eng       Date:  2017-12-01       Impact factor: 2.097

3.  Oversized Biodegradable Arterial Grafts Promote Enhanced Neointimal Tissue Formation.

Authors:  Cameron Best; Takuma Fukunishi; Joseph Drews; Ramak Khosravi; Kan Hor; Nathan Mahler; Tai Yi; Jay D Humphrey; Jed Johnson; Christopher K Breuer; Narutoshi Hibino
Journal:  Tissue Eng Part A       Date:  2018-05-10       Impact factor: 3.845

4.  Flow dynamics across end-to-end vascular bypass graft anastomoses.

Authors:  Y H Kim; K B Chandran; T J Bower; J D Corson
Journal:  Ann Biomed Eng       Date:  1993 Jul-Aug       Impact factor: 3.934

5.  A Rabbit Model of Durable Transgene Expression in Jugular Vein to Common Carotid Artery Interposition Grafts.

Authors:  Lianxiang Bi; Bradley K Wacker; David A Dichek
Journal:  J Vis Exp       Date:  2018-09-10       Impact factor: 1.355

6.  Hemodynamic Shear Stress and Endothelial Dysfunction in Hemodialysis Access.

Authors:  Michelle K Fitts; Daniel B Pike; Kasey Anderson; Yan-Ting Shiu
Journal:  Open Urol Nephrol J       Date:  2014

Review 7.  Coronary artery bypass grafting hemodynamics and anastomosis design: a biomedical engineering review.

Authors:  Dhanjoo N Ghista; Foad Kabinejadian
Journal:  Biomed Eng Online       Date:  2013-12-13       Impact factor: 2.819

8.  Toward a patient-specific tissue engineered vascular graft.

Authors:  Cameron Best; Robert Strouse; Kan Hor; Victoria Pepper; Amy Tipton; John Kelly; Toshiharu Shinoka; Christopher Breuer
Journal:  J Tissue Eng       Date:  2018-03-16       Impact factor: 7.813

9.  3D Simulation Analysis of Central Shunt in Patient-Specific Hemodynamics: Effects of Varying Degree of Pulmonary Artery Stenosis and Shunt Diameters.

Authors:  Jiawei Liu; Haiyun Yuan; Neichuan Zhang; Xiangyu Chen; Chengbin Zhou; Meiping Huang; Qifei Jian; Jian Zhuang
Journal:  Comput Math Methods Med       Date:  2020-02-14       Impact factor: 2.238

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.