Literature DB >> 27784051

Stripe artifact elimination based on nonsubsampled contourlet transform for light sheet fluorescence microscopy.

Xiao Liang1, Yali Zang1, Di Dong1, Liwen Zhang2, Mengjie Fang1, Xin Yang1, Alicia Arranz3, Jorge Ripoll4, Hui Hui1, Jie Tian1.   

Abstract

Stripe artifacts, caused by high-absorption or high-scattering structures in the illumination light path, are a common drawback in both unidirectional and multidirectional light sheet fluorescence microscopy (LSFM), significantly deteriorating image quality. To circumvent this problem, we present an effective multidirectional stripe remover (MDSR) method based on nonsubsampled contourlet transform (NSCT), which can be used for both unidirectional and multidirectional LSFM. In MDSR, a fast Fourier transform (FFT) filter is designed in the NSCT domain to shrink the stripe components and eliminate the noise. Benefiting from the properties of being multiscale and multidirectional, MDSR succeeds in eliminating stripe artifacts in both unidirectional and multidirectional LSFM. To validate the method, MDSR has been tested on images from a custom-made unidirectional LSFM system and a commercial multidirectional LSFM system, clearly demonstrating that MDSR effectively removes most of the stripe artifacts. Moreover, we performed a comparative experiment with the variational stationary noise remover and the wavelet-FFT methods and quantitatively analyzed the results with a peak signal-to-noise ratio, showing an improved noise removal when using the MDSR method.

Mesh:

Year:  2016        PMID: 27784051     DOI: 10.1117/1.JBO.21.10.106005

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  6 in total

1.  Imaging neural events in zebrafish larvae with linear structured illumination light sheet fluorescence microscopy.

Authors:  Yang Liu; Savannah Dale; Rebecca Ball; Ariel J VanLeuven; Andrew Sornborger; James D Lauderdale; Peter Kner
Journal:  Neurophotonics       Date:  2019-03-05       Impact factor: 3.593

2.  Stripe artifact reduction for digital scanned structured illumination light sheet microscopy.

Authors:  Yang Liu; James D Lauderdale; Peter Kner
Journal:  Opt Lett       Date:  2019-05-15       Impact factor: 3.776

3.  Elimination of stripe artifacts in light sheet fluorescence microscopy using an attention-based residual neural network.

Authors:  Zechen Wei; Xiangjun Wu; Wei Tong; Suhui Zhang; Xin Yang; Jie Tian; Hui Hui
Journal:  Biomed Opt Express       Date:  2022-02-07       Impact factor: 3.732

Review 4.  Multiscale light-sheet for rapid imaging of cardiopulmonary system.

Authors:  Yichen Ding; Jianguo Ma; Adam D Langenbacher; Kyung In Baek; Juhyun Lee; Chih-Chiang Chang; Jeffrey J Hsu; Rajan P Kulkarni; John Belperio; Wei Shi; Sara Ranjbarvaziri; Reza Ardehali; Yin Tintut; Linda L Demer; Jau-Nian Chen; Peng Fei; René R Sevag Packard; Tzung K Hsiai
Journal:  JCI Insight       Date:  2018-08-23

5.  Multidirectional digital scanned light-sheet microscopy enables uniform fluorescence excitation and contrast-enhanced imaging.

Authors:  Adam K Glaser; Ye Chen; Chengbo Yin; Linpeng Wei; Lindsey A Barner; Nicholas P Reder; Jonathan T C Liu
Journal:  Sci Rep       Date:  2018-09-17       Impact factor: 4.379

6.  Multiscale imaging of colitis in mice using confocal laser endomicroscopy, light-sheet fluorescence microscopy, and magnetic resonance imaging.

Authors:  Tianmeng Li; Hui Hui; Chaoen Hu; He Ma; Xin Yang; Jie Tian
Journal:  J Biomed Opt       Date:  2019-01       Impact factor: 3.170

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.