| Literature DB >> 27782095 |
Sandra Sendra1,2, Jaime Lloret3, Jose Miguel Jimenez4, Joel J P C Rodrigues5,6,7.
Abstract
Video surveillance is needed to control many activities performed in underwater environments. The use of wired media can be a problem since the material specially designed for underwater environments is very expensive. In order to transmit the images and videos wirelessly under water, three main technologies can be used: acoustic waves, which do not provide high bandwidth, optical signals, although the effect of light dispersion in water severely penalizes the transmitted signals and therefore, despite offering high transfer rates, the maximum distance is very small, and electromagnetic (EM) waves, which can provide enough bandwidth for video delivery. In the cases where the distance between transmitter and receiver is short, the use of EM waves would be an interesting option since they provide high enough data transfer rates to transmit videos with high resolution. This paper presents a practical study of the behavior of EM waves at 2.4 GHz in freshwater underwater environments. First, we discuss the minimum requirements of a network to allow video delivery. From these results, we measure the maximum distance between nodes and the round trip time (RTT) value depending on several parameters such as data transfer rate, signal modulations, working frequency, and water temperature. The results are statistically analyzed to determine their relation. Finally, the EM waves' behavior is modeled by a set of equations. The results show that there are some combinations of working frequency, modulation, transfer rate and temperature that offer better results than others. Our work shows that short communication distances with high data transfer rates is feasible.Entities:
Keywords: 2.4 GHz; electromagnetic waves; freshwater; modulations; underwater communications; underwater video surveillance; underwater wireless sensor network (UWSN); video transmission
Year: 2016 PMID: 27782095 PMCID: PMC5087553 DOI: 10.3390/s16101769
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Parameters of videos.
| Frame Frequency | Parameter | Value |
|---|---|---|
| 30 fps | Resolution | 800 × 600; 852 × 480; 1024 × 768; 1280 × 720; 1280 × 1024; |
| File format | *.mp4 | |
| Bit Rate | Variable | |
| 60 fps | Resolution | 800 × 600; 852 × 480; 1024 × 768; 1280 × 720; 1280 × 1024; |
| File format | *.mp4 | |
| Bit Rate | Variable |
Figure 1Test bench for video characterization.
Figure 2Size of files in MB.
Figure 3Bandwidth for videos at 30 fps.
Figure 4Bandwidth for videos at 60 fps.
Figure 5Maximum and average data transfer rate for each video at 30 fps and 60 fps.
Figure 6Preliminary test to check the effect of air gap. (a) distance between antenna and water: 100 cm; (b) distance between antenna and water: 2.1 cm.
Figure 7Swimming pool where measures have been taken.
Parameters analyzed in the tests performed.
| Modulation | Parameter | Value |
|---|---|---|
| BPSK | Temperatures | 16 °C, 18 °C, 20 °C, 22 °C, 26 °C |
| Data transfer Rates | 1 Mbps | |
| Frequencies tested | 2412 MHz, 2417 MHz, 2422 MHz, 2427 MHz, 2432MHz, 2437 MHz, 2442 MHz, 2447 MHz, 2452 MHz, 2457 MHz, 2462 MHz | |
| QPSK | Temperatures | 16 °C, 18 °C, 20 °C, 22 °C, 26 °C |
| Data transfer Rates | 2 Mbps | |
| Frequencies tested | 2412 MHz, 2417 MHz, 2422 MHz, 2427 MHz, 2432 MHz, 2437 MHz, 2442 MHz, 2447 MHz, 2452 MHz, 2457 MHz, 2462 MHz | |
| CCK (Complementary Code Keying) | Temperatures | 16 °C, 18 °C, 20 °C, 22 °C, 26 °C |
| Data transfer Rates | 5.5 Mbps, 11 Mbps | |
| Frequencies tested | 2412 MHz, 2417 MHz, 2422 MHz, 2427 MHz, 2432 MHz, 2437 MHz, 2442 MHz, 2447 MHz, 2452 MHz, 2457 MHz, 2462 MHz | |
| OFDM | Temperatures | 16 °C, 18 °C, 20 °C, 22 °C |
| Data transfer Rates | 6 Mbps, 9 Mbps, 12 Mbps, 18 Mbps, 22 Mbps, 24 Mbps, 36 Mbps, 48 Mbps, 54 Mbps | |
| Frequencies tested | 2412 MHz, 2417 MHz, 2422 MHz, 2427 MHz, 2432 MHz, 2437 MHz, 2442 MHz, 2447 MHz, 2452 MHz, 2457 MHz, 2462 MHz |
Mean values to determine whether factors has some effect over the variable to be analyzed.
| Factor 2 (β) | ||||||
|---|---|---|---|---|---|---|
| Levels | 1 | 2 | … | J | Mean per Row | |
| 1 | Y11 | Y12 | … | Y1J | ||
| 2 | Y21 | Y22 | … | Y2J | ||
| … | … | … | … | … | … | |
| I | YI1 | YI2 | … | YIJ | ||
| Mean per Column |
|
| ... |
|
| |
Figure 8Maximum distances for BPSK.
Calculation of residuals for BPSK.
| Data Transfer Rates | 2412 MHz | 2417 MHz | 2422 MHz | 2427 MHz | 2432 MHz | 2437 MHz | 2442 MHz | 2447 MHz | 2452 MHz | 2457 MHz | 2462 MHz |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 Mbps at 16 °C | 2.50 | 1.80 | 0.70 | 0.80 | 2.20 | 1.10 | 1.30 | 1.75 | 2.00 | - | - |
| 1 Mbps at 18 °C | 1.00 | 0.30 | 0.80 | 1.20 | 0.20 | 1.10 | 0.70 | 0.25 | 0.01 | - | - |
| 1 Mbps at 20 °C | 3.50 | 2.70 | 2.70 | 3.80 | 1.80 | 1.40 | 0.80 | 1.75 | 1.00 | 0.1 | 0.2 |
| 1 Mbps at 22 °C | 4.50 | 3.70 | 1.20 | 0.80 | 2.20 | 2.10 | 3.70 | 3.25 | 3.00 | - | - |
| 1 Mbps at 26 °C | 4.50 | 4.30 | 3.80 | 4.20 | 2.80 | 2.90 | 2.30 | - | - | - | - |
ANOVA for BPSK.
| Origin of Variations | Sum of Squares | Degree of Freedom | Average Squares | F | Probability | Critical Value for F |
|---|---|---|---|---|---|---|
| Temperatures | 568.154545 | 4 | 142.038636 | 7.60026754 | 0.00011845 | 2.60597495 |
| Frequency | 2321.54545 | 10 | 232.154545 | 12.4222303 | 1.9998 × 10−9 | 2.07724805 |
| Error | 747.545455 | 40 | 18.6886364 | |||
| Total | 3637.24545 | 54 |
Figure 9Maximum distances for QPSK.
Calculation of residuals for QPSK.
| Data Transfer Rates | 2412 MHz | 2417 MHz | 2422 MHz | 2427 MHz | 2432 MHz | 2437 MHz | 2442 MHz | 2447 MHz | 2452 MHz | 2457 MHz | 2462 MHz |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 Mbps at 16 °C | 1.7 | 1.7 | 0.7 | 0.8 | 2.2 | 0.5 | 1.3 | 1.2 | 1.375 | - | - |
| 2 Mbps at 18 °C | 1.2 | 0.2 | 0.8 | 1.2 | 0.2 | 0.5 | 0.7 | 0.8 | 1.375 | - | - |
| 2 Mbps at 20 °C | 3.3 | 2.3 | 2.7 | 3.8 | 1.8 | 2 | 0.8 | 1.2 | 0.375 | 0.1 | 0.15 |
| 2 Mbps at 22 °C | 4.3 | 3.8 | 1.2 | 0.8 | 2.2 | 4.5 | 3.7 | 3.8 | 3.125 | - | - |
| 2 Mbps at 26 °C | 4.7 | 4.2 | 3.8 | 4.2 | 2.8 | 3.5 | 2.3 | 2.2 | - | - | - |
ANOVA for QPSK.
| Origin of Variations | Sum of Squares | Degree of Freedom | Average Squares | F | Probability | Critical Value for F |
|---|---|---|---|---|---|---|
| Temperatures | 403.3 | 4 | 100.825 | 6.71606994 | 0.00031136 | 2.60597495 |
| Frequency | 2384.72727 | 10 | 238.472727 | 15.8849444 | 5.3453 × 10−11 | 2.07724805 |
| Error | 600.5 | 40 | 15.0125 | |||
| Total | 3388.52727 | 54 |
Figure 10Maximum distances for CCK.
Calculation of residuals for CCK at 5.5 Mbps.
| Data Transfer Rates | 2412 MHz | 2417 MHz | 2422 MHz | 2427 MHz | 2432 MHz | 2437 MHz | 2442 MHz | 2447 MHz | 2452 MHz | 2457 MHz | 2462 MHz |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 5.5 Mbps at 16 °C | 1.7 | 1.7 | 0.7 | 0.8 | 2.2 | 0.5 | 1.3 | 1.2 | 1.375 | - | - |
| 5.5 Mbps at 18 °C | 1.2 | 0.2 | 0.8 | 1.2 | 0.2 | 0.5 | 0.7 | 0.8 | 1.375 | - | - |
| 5.5 Mbps at 20 °C | 3.3 | 2.3 | 2.7 | 3.8 | 1.8 | 2 | 0.8 | 1.2 | 0.375 | 0.12 | 0.05 |
| 5.5 Mbps at 22 °C | 4.3 | 3.8 | 1.2 | 0.8 | 2.2 | 4.5 | 3.7 | 3.8 | 3.125 | - | - |
| 5.5 Mbps at 26 °C | 4.7 | 4.2 | 3.8 | 4.2 | 2.8 | 3.5 | 2.3 | 2.2 | - | - | - |
Calculation of residuals for CCK at 11 Mbps.
| Data Transfer Rates | 2412 MHz | 2417 MHz | 2422 MHz | 2427 MHz | 2432 MHz | 2437 MHz | 2442 MHz | 2447 MHz | 2452 MHz | 2457 MHz | 2462 MHz |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 11 Mbps at 16 °C | 1.7 | 1.1 | 0.1 | 1.4 | 1.4 | 1.5 | 1.3 | 1.75 | 1 | - | - |
| 11 Mbps at 18 °C | 1.2 | 0.4 | 0.6 | 1.1 | 0.4 | 2 | 0.7 | 0.25 | 2 | - | - |
| 11 Mbps at 20 °C | 3.3 | 2.4 | 2.9 | 2.9 | 1.6 | 1.5 | 0.8 | 1.75 | 0.07 | 0.2 | 3.3 |
| 11 Mbps at 22 °C | 4.3 | 1.9 | 1.4 | 0.9 | 2.4 | 4.5 | 3.7 | 3.25 | 3 | - | - |
| 11 Mbps at 26 °C | 4.7 | 3.6 | 3.6 | 4.1 | 2.6 | 3.5 | 2.3 | - | - | - | - |
ANOVA for CCK.
| Origin of Variations | Sum of Squares | Degree of Freedom | Average Squares | F | Probability | Critical Value for F |
|---|---|---|---|---|---|---|
| Temperatures | 1134.11136 | 9 | 126.012374 | 7.79263227 | 2.0984 × 10−8 | 1.98559496 |
| Frequency | 4668.09091 | 10 | 466.809091 | 28.8675745 | 6.1007 × 10−24 | 1.93756679 |
| Error | 1455.36364 | 90 | 16.1707071 | |||
| Total | 7257.56591 | 109 |
Figure 11Maximum distances for OFDM at 16 °C.
Figure 12Maximum distances for OFDM at 18 °C.
Figure 13Maximum distances for OFDM at 20 °C.
Figure 14Maximum distances for OFDM at 22 °C.
Calculation of residuals for OFDM at 6 Mbps.
| Data Transfer Rates | 2412 MHz | 2417 MHz | 2422 MHz | 2427 MHz | 2432 MHz | 2437 MHz | 2442 MHz | 2447 MHz | 2452 MHz | 2457 MHz | 2462 MHz |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 6 Mbps at 16 °C | 2.875 | 2.625 | 1 | 0.01 | 1.5 | 0.625 | 1.875 | 1.625 | 1.25 | - | - |
| 6 Mbps at 18 °C | 2.375 | 1.125 | 1.5 | 2 | 0.5 | 0.375 | 0.125 | 0.125 | 1.25 | - | - |
| 6 Mbps at 20 °C | 2.125 | 0.875 | 2 | 2 | 2.5 | 3.125 | 1.375 | 1.625 | 0.25 | 0.03 | 0.22 |
| 6 Mbps at 22 °C | 3.125 | 2.875 | 0.5 | 0.02 | 1.5 | 3.375 | 3.125 | 3.375 | 2.75 | - | - |
Calculation of residuals for OFDM at 9 Mbps.
| Data Transfer Rates | 2412 MHz | 2417 MHz | 2422 MHz | 2427 MHz | 2432 MHz | 2437 MHz | 2442 MHz | 2447 MHz | 2452 MHz | 2457 MHz | 2462 MHz |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 9 Mbps at 16 °C | 2.875 | 2.5 | 0.875 | 0.02 | 1.5 | 0.625 | 1.875 | 1.625 | 1 | - | - |
| 9 Mbps at 18 °C | 2.375 | 1 | 1.375 | 2 | 0.5 | 0.375 | 0.125 | 0.125 | 2 | - | - |
| 9 Mbps at 20 °C | 2.125 | 1.5 | 1.625 | 2 | 2.5 | 3.125 | 1.375 | 1.625 | 0.03 | 0.06 | 0.03 |
| 9 Mbps at 22 °C | 3.125 | 2 | 0.625 | 0.03 | 1.5 | 3.375 | 3.125 | 3.375 | 3 | - | - |
Calculation of residuals for OFDM at 12 Mbps.
| Data Transfer Rates | 2412 MHz | 2417 MHz | 2422 MHz | 2427 MHz | 2432 MHz | 2437 MHz | 2442 MHz | 2447 MHz | 2452 MHz | 2457 MHz | 2462 MHz |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 12 Mbps at 16 °C | 2.875 | 2.375 | 1 | 0.5 | 0.75 | 2.375 | 1.5 | 1.375 | 1.5 | - | - |
| 12 Mbps at 18 °C | 2.375 | 0.375 | 1.5 | 2.5 | 0.25 | 1.125 | 0 | 0.125 | 2.5 | - | - |
| 12 Mbps at 20 °C | 2.125 | 1.125 | 2 | 3.5 | 2.25 | 2.375 | 1.5 | 1.875 | 0.5 | 0.5 | 0.08 |
| 12 Mbps at 22 °C | 3.125 | 1.625 | 0.5 | 0.5 | 1.75 | 3.625 | 3 | 3.125 | 4.5 | - | - |
Calculation of residuals for OFDM at 18 Mbps.
| Data Transfer Rates | 2412 MHz | 2417 MHz | 2422 MHz | 2427 MHz | 2432 MHz | 2437 MHz | 2442 MHz | 2447 MHz | 2452 MHz | 2457 MHz | 2462 MHz |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 18 Mbps at 16 °C | 2.875 | 2.125 | 1 | 0.5 | 0.75 | 2.375 | 1.5 | 1.25 | 1.5 | - | - |
| 18 Mbps at 18 °C | 2.375 | 0.125 | 1.5 | 2 | 0.25 | 1.125 | 0 | 0.25 | 2.5 | - | - |
| 18 Mbps at 20 °C | 2.125 | 1.375 | 2 | 2 | 2.25 | 2.375 | 1.5 | 1.75 | 0.5 | 0.03 | 0.01 |
| 18 Mbps at 22 °C | 3.125 | 0.875 | 0.5 | 0.01 | 1.75 | 3.625 | 3 | 3.25 | 4.5 | - | - |
Calculation of residuals for OFDM at 22 Mbps.
| Data Transfer Rates | 2412 MHz | 2417 MHz | 2422 MHz | 2427 MHz | 2432 MHz | 2437 MHz | 2442 MHz | 2447 MHz | 2452 MHz | 2457 MHz | 2462 MHz |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 22 Mbps at 16 °C | 3 | 2 | 1 | 0.07 | 0.5 | 2 | 1.5 | 1.25 | 1.5 | - | - |
| 22 Mbps at 18 °C | 2 | 0.5 | 1.5 | 2 | 1.5 | 0.1 | 0.09 | 0.25 | 2.5 | - | - |
| 22 Mbps at 20 °C | 2 | 1 | 2 | 2 | 0.5 | 2 | 1.5 | 1.75 | 0.5 | 0.02 | 0.01 |
| 22 Mbps at 22 °C | 3 | 1.5 | 0.5 | 0.2 | 0.5 | 4 | 3 | 3.25 | 4.5 | -- |
Calculation of residuals for OFDM at 24 Mbps.
| Data Transfer Rates | 2412 MHz | 2417 MHz | 2422 MHz | 2427 MHz | 2432 MHz | 2437 MHz | 2442 MHz | 2447 MHz | 2452 MHz | 2457 MHz | 2462 MHz |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 24 Mbps at 16 °C | 3 | 2 | 1 | 0.09 | 0.5 | 2 | 1.5 | 1.25 | 1.5 | ||
| 24 Mbps at 18 °C | 2 | 0.5 | 1.5 | 2 | 1.5 | 0.05 | 0.04 | 0.25 | 2.5 | ||
| 24 Mbps at 20 °C | 2 | 1 | 2 | 2 | 0.5 | 2 | 1.5 | 1.75 | 0.5 | 0.1 | 0.2 |
| 24 Mbps at 22 °C | 3 | 1.5 | 0.5 | 0.1 | 0.5 | 4 | 3 | 3.25 | 4.5 | - | - |
Calculation of residuals for OFDM at 36 Mbps.
| Data Transfer Rates | 2412 MHz | 2417 MHz | 2422 MHz | 2427 MHz | 2432 MHz | 2437 MHz | 2442 MHz | 2447 MHz | 2452 MHz | 2457 MHz | 2462 MHz |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 36 Mbps at 16 °C | 3 | 2 | 0.25 | 0.1 | 0.125 | 2 | 1.5 | 1.25 | 1.5 | - | - |
| 36 Mbps at 18 °C | 2 | 0.5 | 1.75 | 2 | 2.375 | 0.13 | 0.08 | 0.25 | 2.5 | - | - |
| 36 Mbps at 20 °C | 2 | 1 | 1.75 | 2 | 2.125 | 2 | 1.5 | 1.75 | 0.5 | 0.01 | 0.02 |
| 36 Mbps at 22 °C | 3 | 1.5 | 0.25 | 0.12 | 0.125 | 4 | 3 | 3.25 | 4.5 | - | - |
Calculation of residuals for OFDM at 48 Mbps.
| Data Transfer Rates | 2412 MHz | 2417 MHz | 2422 MHz | 2427 MHz | 2432 MHz | 2437 MHz | 2442 MHz | 2447 MHz | 2452 MHz | 2457 MHz | 2462 MHz |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 48 Mbps at 16 °C | 3 | 2 | 0.125 | 0.01 | 0.25 | 1.875 | 1.625 | 1 | 1.25 | - | - |
| 48 Mbps at 18 °C | 2 | 0.5 | 1.625 | 2 | 1.25 | 0.125 | 0.125 | 0.03 | 2.25 | - | - |
| 48 Mbps at 20 °C | 2 | 1 | 1.375 | 2 | 1.75 | 1.875 | 1.125 | 2 | 1.25 | 0.01 | 0.02 |
| 48 Mbps at 22 °C | 3 | 1.5 | 0.375 | 0.02 | 0.25 | 3.625 | 2.875 | 3 | 4.75 | - | - |
Calculation of residuals for OFDM at 54 Mbps.
| Data Transfer Rates | 2412 MHz | 2417 MHz | 2422 MHz | 2427 MHz | 2432 MHz | 2437 MHz | 2442 MHz | 2447 MHz | 2452 MHz | 2457 MHz | 2462 MHz |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 54 Mbps at 16 °C | 3 | 2.375 | 0.125 | 0.03 | 0.25 | 2 | 1.625 | 1.125 | 1.25 | - | - |
| 54 Mbps at 18 °C | 2 | 0.875 | 1.625 | 2 | 1.25 | 0.02 | 0.125 | 0.375 | 2.25 | - | - |
| 54 Mbps at 20 °C | 2 | 0.625 | 1.375 | 2 | 1.75 | 2 | 1.125 | 2.125 | 1.25 | 0.01 | 0.02 |
| 54 Mbps at 22 °C | 3 | 2.625 | 0.375 | 0.01 | 0.25 | 4 | 2.875 | 2.875 | 4.75 | - | - |
ANOVA for OFDM.
| Origin of variations | Sum of squares | Degree of Freedom | Average Squares | F | Probability | Critical Value for F |
|---|---|---|---|---|---|---|
| Temperatures | 1270.41604 | 35 | 36.297601 | 3.24754764 | 1.3182 × 10−8 | 1.45688671 |
| Frequency | 17105.803 | 10 | 1710.5803 | 153.04568 | 2.998 × 10−121 | 1.85779125 |
| Error | 3911.92424 | 350 | 11.1769264 | |||
| Total | 22288.1433 | 395 |
Figure 15Values of RTT in ms for 16 °C.
Figure 16Measurements of RTT in ms for 18 °C.
Figure 17Values of RTT in ms for 20 °C.
Figure 18Values of RTT in ms for 22 °C.
Figure 19Values of RTT in ms for 26 °C.
Figure 20Estimated maximum distances for BPSK modulation.
Figure 21Estimated maximum distances for QPSK modulation.
Figure 22Estimated maximum distances for OFDM modulation.
Figure 23Estimated maximum distances for CCK transmission scheme.