Literature DB >> 2778087

Probing site configuration in patients with untreated periodontitis. A study of horizontal positional error.

T L Watts1.   

Abstract

This study examined the morphology of 487 probing sites in patients with untreated periodontitis, using a constant force probe (0.25 N, 0.5 mm) and flexible stent with guide grooves, at 3 adjacent points per site, 6 sites per tooth. Sites were classified into 9 configuration types according to the relationship of the 3 adjacent points. Duplicate measurements were made and sites were analysed with special reference to whether a slight horizontal movement was likely at the second examination. 60% of individual point probing measurements were exactly reproduced, but only 23% of site configurations. 65% of configuration change was accountable on the basis of slight horizontal shift of the probe. Only 13% of configurations required the postulate of other forms of probing error. These results suggest that probing reproducibility is not always an indication of site reproducibility, and that the variation of probe position in the transverse plane is an important source of probing error, even when a stent is used.

Entities:  

Mesh:

Year:  1989        PMID: 2778087     DOI: 10.1111/j.1600-051x.1989.tb02331.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  7 in total

1.  Effectiveness of a personalized device in the evaluation of mandibular second molar periodontal healing after surgical extraction of adjacent third molar.

Authors:  Roberto Pippi
Journal:  Ann Stomatol (Roma)       Date:  2014-02-04

Review 2.  Methodological issues in epidemiological studies of periodontitis--how can it be improved?

Authors:  Roos Leroy; Kenneth A Eaton; Amir Savage
Journal:  BMC Oral Health       Date:  2010-04-21       Impact factor: 2.757

3.  Accuracy of probing attachment levels using a new computerized cemento-enamel junction probe.

Authors:  R Deepa; Shobha Prakash
Journal:  J Indian Soc Periodontol       Date:  2012-01

4.  Improved accuracy in periodontal pocket depth measurement using optical coherence tomography.

Authors:  Sul-Hee Kim; Se-Ryong Kang; Hee-Jung Park; Jun-Min Kim; Won-Jin Yi; Tae-Il Kim
Journal:  J Periodontal Implant Sci       Date:  2017-02-28       Impact factor: 2.614

5.  An Evaluation of the Effectiveness of the Modalities Used to Deliver Electronic Health Interventions for Chronic Pain: Systematic Review With Network Meta-Analysis.

Authors:  Brian W Slattery; Stephanie Haugh; Laura O'Connor; Kady Francis; Christopher P Dwyer; Siobhán O'Higgins; Jonathan Egan; Brian E McGuire
Journal:  J Med Internet Res       Date:  2019-07-17       Impact factor: 5.428

6.  Clinical attachment loss: estimation by direct and indirect methods.

Authors:  Viviane Leal Barbosa; Patricia D Melchiors Angst; Amanda Finger Stadler; Rui V Oppermann; Sabrina Carvalho Gomes
Journal:  Int Dent J       Date:  2016-02-05       Impact factor: 2.607

7.  Digital scanning is more accurate than using a periodontal probe to measure the keratinized tissue width.

Authors:  Jung-Seok Lee; Yoon-Sun Jeon; Franz-Josef Strauss; Hoi-In Jung; Reinhard Gruber
Journal:  Sci Rep       Date:  2020-02-28       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.